Applied laboratory testing- 11,12,13,14,15

Applied laboratory testing- 11,12,13,14,15

University

63 Qs

quiz-placeholder

Similar activities

AP Bio Evolution

AP Bio Evolution

11th Grade - University

60 Qs

Routt Meiosis (& Mitosis) Master

Routt Meiosis (& Mitosis) Master

9th Grade - University

62 Qs

Levels of organization/ Organ system/Homeostasis

Levels of organization/ Organ system/Homeostasis

9th Grade - University

61 Qs

XI BOTANY (Vol 1 & 2)

XI BOTANY (Vol 1 & 2)

11th Grade - University

60 Qs

Human Bio ch 1-4 review: COL, chemistry, cells, tissues

Human Bio ch 1-4 review: COL, chemistry, cells, tissues

12th Grade - University

63 Qs

Histology Test Review

Histology Test Review

11th Grade - University

60 Qs

Control of Microbial Growth

Control of Microbial Growth

University

60 Qs

Applied laboratory testing- 11,12,13,14,15

Applied laboratory testing- 11,12,13,14,15

Assessment

Quiz

Biology

University

Medium

Created by

Nandini Gautam (Virohan Fbd)

Used 13+ times

FREE Resource

63 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Does the order of draw is the same for specimens collected by syringe , tube holder or into tuber pre evacuated at the time of collection.

yes

no

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many times do we need to invert the tube with an anticoagulant clot activator to prevent clotting?

5 times

10 times

15 times

both A & B

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of tube is used for STAT testing?

grey top tube

blue top tube

green top tube

red top tubes

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following electrolyte of blood are not chelated by EDTA?

Mg2+

Cl+

Ca2+

Zn2+

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

K- EDTA tube contamination will be responsible for which of the following conditions?

inhibits the alkaline phosphatase test

elevated potassium level

falsely decreases the electrolytes levels

all of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What factor(s) do you think have contributed to this discrepancy?

machine was not calibrated after major repair

the replaced part was the wrong one

the personnel did not perform correct calibration method

the personnel did not perform correct quality control method

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Choose the correct option regarding the term analytical errors?

the errors happen during the sample collection procedure

the errors happen after the sample testing procedure

the errors happen during the testing process

All of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?