GMJ 9189 Phase 3 Central heating MCQ

GMJ 9189 Phase 3 Central heating MCQ

Professional Development

20 Qs

quiz-placeholder

Similar activities

Piggy quiz

Piggy quiz

KG - Professional Development

17 Qs

Neurotransmitter

Neurotransmitter

University - Professional Development

15 Qs

UTAR Industrial Session

UTAR Industrial Session

University - Professional Development

15 Qs

GE102 - Midterm Quiz

GE102 - Midterm Quiz

Professional Development

16 Qs

Labor Relations and Negotations 1

Labor Relations and Negotations 1

University - Professional Development

15 Qs

OBM Revision

OBM Revision

Professional Development

20 Qs

MBIG agm quizizz

MBIG agm quizizz

Professional Development

16 Qs

TechMD-IEC Module 1 Quiz

TechMD-IEC Module 1 Quiz

Professional Development

20 Qs

GMJ 9189 Phase 3 Central heating MCQ

GMJ 9189 Phase 3 Central heating MCQ

Assessment

Quiz

Other

Professional Development

Practice Problem

Hard

Created by

Glen Johnson

Used 48+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which British Standard covers the method for the calculation of design heating loads?

BS EN 12828:2003

BS EN 12831:2003

BS EN 14336:2004

BS EN 1264-1:1998

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the measurement of the U-value?

W/m²K

kJ/m²C

W/kg/K

J/m³K

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct formula to determine the heat loss from a space through air changes and ventilation?

m² x Δt x 1.33

m² x Δt x U-value

m³ x QTY x Δt0.33

m³ x U-value x QTY x 3

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are the likely effects of oversizing a heating system?

Reduced energy usage, as systems produce enough heat quickly before shutting off for longer periods

Reduced life expectancy of heat emitters, which often overheat due to higher temperatures

Greater risk of burns/scalds, due to excess temperatures within the system and increased boiler combustion efficiency

Reduced energy efficiency, as boilers 'hunt', and greater initial outlay costs

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the most suitable external design temperature for a house with normal sheltered exposure in England and Wales?

-1°C

-3°C

-4°C

-5°C

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct formula to determine the heat loss through a surface such as a wall or window?

m² x Δt x 1.33

m² x Δt x U-value

m³ x QTY x Δt x 0.33

m³ x U-value x QTY x 3

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A radiator has a temperature of 70°C at the inlet and 50°C at the outlet. What is the MWT of the radiator?

20°C

40°C

50°C

60°C

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?