units 3-5

units 3-5

Professional Development

20 Qs

quiz-placeholder

Similar activities

2018 IPC CH 6A Study Quiz

2018 IPC CH 6A Study Quiz

Professional Development

25 Qs

2018 Mechanical Chapter 10

2018 Mechanical Chapter 10

Professional Development

25 Qs

Medical Gas Systems 2021 101-125

Medical Gas Systems 2021 101-125

Professional Development

25 Qs

2018 IPC CH 6B Study Quiz

2018 IPC CH 6B Study Quiz

Professional Development

25 Qs

2018 IPC CH 5 Study Quiz

2018 IPC CH 5 Study Quiz

Professional Development

25 Qs

Chapter 3: Institutional Fixtures and Equipment

Chapter 3: Institutional Fixtures and Equipment

Professional Development

16 Qs

2018 IPC CH 4B Quiz

2018 IPC CH 4B Quiz

Professional Development

25 Qs

2018 IPC CH 4B Study Quiz

2018 IPC CH 4B Study Quiz

Professional Development

25 Qs

units 3-5

units 3-5

Assessment

Quiz

Other

Professional Development

Hard

Created by

william kemp

Used 3+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Carbon monoxide shall activate a local alarm when the CO level exceeds ?

10 ppm

5 ppm

15 ppm

20 ppm

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the dew point system temperature exceeds _________, the required alarms shall activate.

42 F

38 F

35 F

21 F

3.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Liquid ring compressors service water and seal water shall be treated to control ____________.

Chlorine

Waterborne pathogens

Hyper chlorination

Electrolosis

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air compressor systems shall have a ___________ means to prevent backflow through all off-cycle compressors.

Manual

Semi- automatic

Automatic

All the above

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air filters shall be located immediately upstream of the ___________.

After coolers

Final line regulator

Pressure indicator

Receiver

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air filters shall be sized for 100% of the system peak calculated demand and be rated for a minimum of _______ percent efficiency @ ________ micron or greater.

95% @ 0.5

98% @ 1

98% @ 0.1

100% @ 1

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air sources shall only be used for____________.

Instrument air

Air-operating devices

Human respiratory applications

All of the above