1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can the cold water supply pressure to a property be identified?

By contacting the local council or using a weir gauge at the kitchen sink

By contacting the local council or using a pressure gauge at the supply to the FOV

By contacting the water undertaker or using a pressure gauge at the cistern-fed outlets

By contacting the water undertaker or using a pressure gauge at the kitchen sink

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What term is given to the length of pipe when all fittings and components are considered during pipe sizing?

Equivalent length

Actual length

Mean length

Velocity length

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended storage capacity of a CWSC supplying cold and hot water to a house?

100 litres minimum

150 litres minimum

230 litres minimum

350 litres minimum

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following factors would not directly affect the pressure and flow rates of pipework?

Pipe diameter

Pipe material

Number of bends

pH level of the water supply

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A boosted cold water system is fitted with a break cistern at low level and a storage cistern at high level. The pump seems to have seized after 'running dry' for some time. What control component within the system is most likely to have failed and allowed this to happen?

Float operated valve within the storage cistern

Float operated level shut-off switch within the storage cistern

Float operated valve within the break cistern

Float operated low level shut-off switch within the break cistern

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How often should a CWSC be checked for contamination and general condition within an apartment block?

Monthly

Quarterly

Half yearly

Annually

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A sentinel outlet may be described as:

a tap at the mid-position within a system

the taps at the furthest and closest locations to the supply

the taps at the highest and lowest points

A tap outlet which is operated the least frequently

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Microsoft

Continue with Microsoft

or continue with

Facebook

Facebook

Apple

Apple

Others

Others

Already have an account?