Chiller troubleshooting

Chiller troubleshooting

University

12 Qs

quiz-placeholder

Similar activities

Feedback Amplifiers

Feedback Amplifiers

University

10 Qs

Unit 1 - Electrical properties of materials - Quiz 1

Unit 1 - Electrical properties of materials - Quiz 1

University

15 Qs

Angular Motion

Angular Motion

University

10 Qs

Quiz for Boyle's Law

Quiz for Boyle's Law

10th Grade - University

10 Qs

year 10 terminal velocity

year 10 terminal velocity

9th Grade - University

15 Qs

Atomic structure

Atomic structure

KG - Professional Development

10 Qs

projectile motion KMS

projectile motion KMS

University

10 Qs

ACDC Machines

ACDC Machines

University

11 Qs

Chiller troubleshooting

Chiller troubleshooting

Assessment

Quiz

Physics

University

Hard

NGSS
HS-PS3-4

Standards-aligned

Created by

Robert Hemmila

Used 4+ times

FREE Resource

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

You are looking at a low pressure chiller and the chiller condenser barrel approach temperature has gradually increased to 9 degrees over a time period of 4 months on a 3 pass evaporator the likely cause is?

The cooling tower fan is not running up to speed.

The sump on the tower needs cleaning.

The chiller condenser barrel has built up with contaminants and needs cleaned.

The condenser water pump is running too slow causing an increased approach.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

High pressure chillers utillizing screw compressors require what because of the high refrigerant flow?

Oil separator

High pressure safety

Flow diversion valve

Electronic expansion valve

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Screw compressors control capacity with?

Suction valve lift

Suction solenoid valve

Slide valve

Inlet vanes

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Screw compressors are used on low pressure chillers.

True

False

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A high pressure chllier locked out on High pressure safety open a likely cause could be?

Dirty chiller barrel

Dirty condenser coil

Low water flow on the evaporator

Low refrigerant charge

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the fan on the cooling tower fails what is likely to happen to the range of the cooling tower?

It will increase but the approach will decrease

It will decrease and the approach will increase

It will increase and the approach will increase

It will decrease and the approach will decrease

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The flow switch interlock is designed to?

start the pump on the chiller

stop the chiller if water flow is not present

start the chiller when water flow starts

stop the chiller when water flow starts

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?