26209 Grounding and bonding

26209 Grounding and bonding

11th Grade

25 Qs

quiz-placeholder

Similar activities

QUIZ 1 : TOPIC 4 [COST VOLUME PROFIT ANALYSIS]

QUIZ 1 : TOPIC 4 [COST VOLUME PROFIT ANALYSIS]

1st Grade - University

20 Qs

Module 6: Social Groups and Organization

Module 6: Social Groups and Organization

11th Grade - Professional Development

20 Qs

Skills for Real World Communication Vocabulary

Skills for Real World Communication Vocabulary

9th - 12th Grade

20 Qs

PHS Dress Code Review

PHS Dress Code Review

9th - 12th Grade

20 Qs

MTA: 98-367 Security Part 2

MTA: 98-367 Security Part 2

KG - Professional Development

20 Qs

Cultural Diversity quiz

Cultural Diversity quiz

9th - 12th Grade

20 Qs

EEE610 Group EE2427A&B Sept 2018

EEE610 Group EE2427A&B Sept 2018

7th Grade - University

20 Qs

Habit 4

Habit 4

2nd Grade - Professional Development

20 Qs

26209 Grounding and bonding

26209 Grounding and bonding

Assessment

Quiz

Professional Development

11th Grade

Hard

Created by

TIMOTHY COLVIN

Used 13+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A ground fault is described as an unintentional ____.

connection between two or more portions of the equipment grounding conductor

open connection between an electrical circuit or equipment and the earth

conducting connection between any of the conductors of an electrical system

electrically conducting connection between an ungrounded conductor of an electrical circuit and the normally non-current-carrying conductors

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a main bonding jumper is required by the NEC®, the jumper cannot be less than what percentage of the area of the largest phase conductor?

12.50%

14%

17.50%

20%

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A ground test utilizing an auxiliary current electrode and an auxiliary potential electrode is known as the ____.

one-point test

three-point tes

six-point test

ten-point test

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If Single-Gang, Nail-on, nonmetallic boxes are used with NM cable, which of the following is true?

No connection to the box is required.

A grounding clip connects the box to the cable.

Electrical tape connects the box to the cable.

A standard electrician’s staple connects the box to the cable.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The fall-of-potential method is used to measure ____.

induced currents

step voltage

earth resistance

touch voltage

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Rod, pipe, and plate electrodes must have a resistance to ground of at least ____.

25 ohms or less

35 ohms or less

45 ohms or less

75 ohms or less

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a separately derived system, the equipment bonding jumper connects the ____.

system housing to the neutral bus bar

system housing to the feeder panel

neutral on the supply side to the equipment housing

neutral bus bar to the grounding electrode conductor

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Discover more resources for Professional Development