Evaporator feed control, Objective 2

Quiz
•
Science
•
University
•
Medium
Andgel Thomas
Used 5+ times
FREE Resource
15 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the main purpose of an evaporator feed controller?
To reduce the temperature on the evaporating side of the system
To control the speed of the compressor
To increase the pressure on the condensing side of the system
To manage the rate of refrigerant flow into the evaporator
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following is NOT a type of evaporator feed control?
Capillary Tube
Float
Expansion Valve
Fixed Orifice
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of a fixed orifice evaporator feed control?
To drastically reduce the pressure and flow of liquid refrigerant
To increase the pressure on the evaporating side of the system
To regulate the temperature in the condenser
To control the speed of the compressor
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the function of a capillary tube evaporator feed control?
To regulate the temperature in the evaporator
To increase the pressure on the condensing side of the system
To reduce the pressure of liquid refrigerant as it passes through
To control the speed of the compressor
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How does a float type evaporator feed control operate?
By regulating the temperature in the evaporator
By controlling the liquid refrigerant level in the receiver or evaporator
By increasing the pressure on the condensing side of the system
By controlling the speed of the compressor
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of an expansion valve in refrigeration systems?
To start and stop refrigerant flow
To control the speed of the compressor
To increase the pressure on the evaporating side of the system
To regulate the temperature in the condenser
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the main difference between a hand expansion valve and an automatic expansion valve?
Hand valve increases pressure while automatic valve decreases pressure
Hand valve is used in large chillers while automatic valve is used in small systems
Hand valve is fixed while automatic valve is adjustable
Hand valve is manually controlled while automatic valve is automatic
Create a free account and access millions of resources
Similar Resources on Wayground
15 questions
Evaporator Feed Control pt 2

Quiz
•
University
16 questions
The Heart

Quiz
•
7th Grade - University
20 questions
Cardiovascular system review

Quiz
•
11th Grade - University
12 questions
Heart chambers and valves

Quiz
•
University
15 questions
Heart Anatomy and Physiology

Quiz
•
12th Grade - University
10 questions
Heart Anatomy Quiz

Quiz
•
University
13 questions
Refrigeration quiz True/false

Quiz
•
University
15 questions
Heat Pump

Quiz
•
University
Popular Resources on Wayground
10 questions
Video Games

Quiz
•
6th - 12th Grade
10 questions
Lab Safety Procedures and Guidelines

Interactive video
•
6th - 10th Grade
25 questions
Multiplication Facts

Quiz
•
5th Grade
10 questions
UPDATED FOREST Kindness 9-22

Lesson
•
9th - 12th Grade
22 questions
Adding Integers

Quiz
•
6th Grade
15 questions
Subtracting Integers

Quiz
•
7th Grade
20 questions
US Constitution Quiz

Quiz
•
11th Grade
10 questions
Exploring Digital Citizenship Essentials

Interactive video
•
6th - 10th Grade
Discover more resources for Science
10 questions
Would you rather...

Quiz
•
KG - University
20 questions
Definite and Indefinite Articles in Spanish (Avancemos)

Quiz
•
8th Grade - University
7 questions
Force and Motion

Interactive video
•
4th Grade - University
10 questions
The Constitution, the Articles, and Federalism Crash Course US History

Interactive video
•
11th Grade - University
7 questions
Figurative Language: Idioms, Similes, and Metaphors

Interactive video
•
4th Grade - University
20 questions
Levels of Measurements

Quiz
•
11th Grade - University
16 questions
Water Modeling Activity

Lesson
•
11th Grade - University
10 questions
ACT English prep

Quiz
•
9th Grade - University