18th Edition Section 2

18th Edition Section 2

Professional Development

15 Qs

quiz-placeholder

Similar activities

Labor Relations and Negotations 1

Labor Relations and Negotations 1

University - Professional Development

15 Qs

KICK OFF  HA

KICK OFF HA

Professional Development

12 Qs

Apprenticeship Study at the AMRC TC (Level 3)

Apprenticeship Study at the AMRC TC (Level 3)

Professional Development

13 Qs

Mahatma Gandhi Ji Quiz

Mahatma Gandhi Ji Quiz

3rd Grade - Professional Development

20 Qs

PKS

PKS

Professional Development

20 Qs

UTAR Industrial Session

UTAR Industrial Session

University - Professional Development

15 Qs

Present Simple & Present Continuous

Present Simple & Present Continuous

Professional Development

20 Qs

Post Test Internal Training TKBT 2 PT APS

Post Test Internal Training TKBT 2 PT APS

Professional Development

20 Qs

18th Edition Section 2

18th Edition Section 2

Assessment

Quiz

Education

Professional Development

Practice Problem

Medium

Created by

Lee Williams

Used 22+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

13. What is the maximum IΔn for and RCD protecting 16 A mobile equipment used outdoors?

100mA

30mA

300mA

500mA

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

14. Which of the following is a method of fault protection?

Placing out of reach

Protection by double or reinforced insulation

Protection by obstacles

Insulation of live parts

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

15. With which of the following methods can both basic and fault protection be achieved?

SELV

Insulation of live parts

FELV

Protection by non-conducting location

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

16. The protective measure by electrical separation provides

Fault protection only

Basic protection only

Fault and basic protection

Undervoltage

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

17. The maximum permissible earth fault loop impedance on a TN system for a socket outlet, used for hand-held equipment and protected by a 20 A fuse to BS 3036 is

1.10 Ω

1.47 Ω

1.68 Ω

2.70 Ω

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

18. The maximum disconnection time for a 16 A final circuit, where U0 = 230 V ac, forming part of a TN system is

5 s

0.2 s

0.4 s

0.1 s

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

19. Extraneous-conductive-parts are provided with protective equipotential bonding to ensure that

The parts are completely isolated from earth

Dangerous potential differences are reduced

The water mains can be used as auxiliary earth electrodes

There is no connection with the circuit protective conductors

Create a free account and access millions of resources