6035 | Drainage systems | LO1.1

6035 | Drainage systems | LO1.1

Professional Development

13 Qs

quiz-placeholder

Similar activities

Construction Inspection 2

Construction Inspection 2

Professional Development

9 Qs

Outside Diameter of Pipe

Outside Diameter of Pipe

Professional Development

10 Qs

AMP - Module1-Test 1

AMP - Module1-Test 1

Professional Development

15 Qs

6035 | Central Heating LO1 Part 1

6035 | Central Heating LO1 Part 1

Professional Development

10 Qs

Thermostatic Expansion Valves TEV TXV

Thermostatic Expansion Valves TEV TXV

Professional Development

9 Qs

L2 Plumbing Common Plumbing Processes Knowledge Test

L2 Plumbing Common Plumbing Processes Knowledge Test

University - Professional Development

14 Qs

Trap losses | Preventions

Trap losses | Preventions

Professional Development

13 Qs

Pre-floor AS/NZ3500.2 Plumbing

Pre-floor AS/NZ3500.2 Plumbing

Professional Development

8 Qs

6035 | Drainage systems | LO1.1

6035 | Drainage systems | LO1.1

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

George Harding

Used 205+ times

FREE Resource

13 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

The section within the red markings is known as:

Soil pipe

Vent pipe

Stub stack

Secondary ventilated stack

2.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which two regulations must all drainage systems comply with within England and Wales?

Part L

Part G

Part H

Part P

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The British Standard number for sanitary installations is:

BS 6700

BS 4488

BS EN 442

BS 6465

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to be compliant with Part H, the depth of a water seal in a trap should not be less than:

25mm

40mm

50mm

75mm

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum gradient of all discharge branches is:

2.5°

1.8°

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum length of pipe that a WC should be positioned from the primary ventilated stack is?

1.7m

3.0m

6.0m

10.0m

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a basin was placed further away than 1.7m from the primary stack, what action should be followed?

Inform the customer that the job cannot be completed.

Inform the local authority of a breach of Building Regulations Part H.

Reposition the basin within the 1.7m tolerance.

Replace the run of pipe for a 40mm pipe.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?