Electrical Practice

Electrical Practice

Professional Development

20 Qs

quiz-placeholder

Similar activities

Internal Auditor (Auditing Process) Online Game 3

Internal Auditor (Auditing Process) Online Game 3

Professional Development

20 Qs

Cultural Competency

Cultural Competency

University - Professional Development

15 Qs

Singleview Account

Singleview Account

Professional Development

20 Qs

Posttest on Differentiated Supervision

Posttest on Differentiated Supervision

Professional Development

15 Qs

EDUCATION

EDUCATION

Professional Development

15 Qs

comparative animals

comparative animals

Professional Development

20 Qs

conhecimentos gerais Super aprendiz

conhecimentos gerais Super aprendiz

Professional Development

15 Qs

Chapter 2 : Manufacturing Cost Concept and Components

Chapter 2 : Manufacturing Cost Concept and Components

University - Professional Development

16 Qs

Electrical Practice

Electrical Practice

Assessment

Quiz

Education

Professional Development

Practice Problem

Hard

Created by

Mr. Know-It-all

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For a grounded electrical system supplied by a feeder or branch circuit, the equipment grounding conductor shall be sized in accordance with ___________.

the ungrounded circuit conductors

the overcurrent protective device

the service entrance conductors

the grounding electrode

Answer explanation

The equipment grounding conductor must be sized according to the overcurrent protective device to ensure it can safely carry fault currents without overheating, providing effective protection for the electrical system.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In movie theaters, all switches for controlling the emergency lighting systems shall be located ______

on the stage

in the lobby

in the managers office

in the projection booth

Answer explanation

In movie theaters, emergency lighting system switches must be easily accessible for safety. Placing them in the lobby ensures quick access for staff during emergencies, making 'in the lobby' the correct choice.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When connecting utilization equipment to a 20-ampere rated branch-circuit that also serves luminaires , the utilization equipment shall have an ampere rating not more than _______.

10 amperes

15 amperes

16 amperes

12 amperes

Answer explanation

When connecting utilization equipment to a 20-ampere branch circuit with luminaires, the equipment's ampere rating must not exceed 10 amperes to ensure safe operation and prevent overload, making 10 amperes the correct choice.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where there are tenant spaces in a retail shopping mall, each occupant shall have access to the main disconnecting means, EXCEPT:

where the service and maintenance are provided by the building management

where there are more than six disconnecting means

where the primary feeder transformer does not exceed 600 volts

where the secondary of the service transformer does not exceed 240 volts to ground

Answer explanation

The correct choice is where the service and maintenance are provided by the building management, as this allows the management to control access to the main disconnecting means, ensuring safety and efficiency.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For lighting systems operating at 30-volts or less, the output circuits of the power supply are to be rated not more than ________.

15 amperes

20 amperes

25 amperes

30 amperes

Answer explanation

For lighting systems at 30-volts or less, the output circuits must not exceed 25 amperes to ensure safety and compliance with electrical standards. Therefore, the correct answer is 25 amperes.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a service riser is installed in a wet location and contains THWN insulated conductors, the wiring method used is ___________

is permitted to be type AC cable

shall be rigid metal conduit

is permitted to be electrical metallic tubing

shall be liquid-tight flexible metal conduit

Answer explanation

In wet locations, THWN insulated conductors can be installed using electrical metallic tubing (EMT), which provides adequate protection against moisture. Other options may not meet the necessary requirements for wet environments.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a 90 ampere, 240-Volt, single phase load is located 225 feet from a panelboard and is supplied with a size 3 awg copper conductors, determine the approximate voltage drop of the conductors.

VD = 2KID / CM K= 12.9

6 V

4 V

8 V

10 V

Answer explanation

Using the formula VD = 2KID / CM, where K = 12.9, I = 90 A, D = 450 ft (225 ft each way), and CM for 3 AWG copper is 83.5, we calculate VD to be approximately 10 V, making 10 V the correct answer.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?