Residential Sewer Line Installation Quiz

Residential Sewer Line Installation Quiz

11th Grade

10 Qs

quiz-placeholder

Similar activities

Airplane Components Review

Airplane Components Review

8th - 11th Grade

16 Qs

Trig 17.1 Amplitude & Period

Trig 17.1 Amplitude & Period

11th - 12th Grade

10 Qs

11 Barbering - Hair Cutting

11 Barbering - Hair Cutting

11th Grade

15 Qs

Graphing Rational Functions

Graphing Rational Functions

11th - 12th Grade

11 Qs

Construction Hand Tools

Construction Hand Tools

9th - 12th Grade

13 Qs

Introduction to Maps U5C4L1  *ML

Introduction to Maps U5C4L1 *ML

9th - 12th Grade

15 Qs

Dress Making - Body Measurement

Dress Making - Body Measurement

7th - 12th Grade

10 Qs

Truss Analysis

Truss Analysis

11th - 12th Grade

11 Qs

Residential Sewer Line Installation Quiz

Residential Sewer Line Installation Quiz

Assessment

Interactive Video

Other

11th Grade

Hard

Created by

Christopher Richard

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum number of toilets a residential house can have before requiring a four-inch pipe?

Five

Two

Three

Four

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a backwater valve in a sewer line?

To reduce the pipe size

To prevent water from flowing back into the house

To filter the water

To increase water pressure

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When is a backwater valve required according to code?

When the sewer line is longer than 100 feet

When the finished floor is higher than the manhole rim elevation

When the finished floor is lower than the next downstream manhole rim elevation

When there are more than three toilets in the house

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why should you avoid hub-on-hub connections in sewer lines?

They can cause leaks

They are more expensive

They are not allowed by code

They are difficult to install

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended height for a cleanout riser before landscaping is completed?

Just above ground level

As high as possible

Slightly below ground level

At ground level

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How should the bell end of a pipe be oriented when running a sewer line?

Pointed upwards

Pointed downwards

Pointed towards the house

Pointed away from the house

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum distance allowed between cleanouts in a sewer line?

100 feet

75 feet

50 feet

150 feet