Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Professional Development

28 Qs

quiz-placeholder

Similar activities

IS 9

IS 9

Professional Development

25 Qs

E103A

E103A

Professional Development

25 Qs

CAP/IT for Applications - 2.5 Managing Electrical Fires

CAP/IT for Applications - 2.5 Managing Electrical Fires

Professional Development

25 Qs

Nat'l Plumbing Code Q4

Nat'l Plumbing Code Q4

University - Professional Development

25 Qs

Basic Electricity

Basic Electricity

Professional Development

30 Qs

RME_Chapter 3

RME_Chapter 3

Professional Development

30 Qs

HV 25 M1

HV 25 M1

Professional Development

23 Qs

2018 Mechanical Chapter 11

2018 Mechanical Chapter 11

Professional Development

25 Qs

Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Assessment

Quiz

Other

Professional Development

Hard

Created by

Amir Karbassi

Used 1+ times

FREE Resource

28 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Determine the minimum conduit size to accommodate 3 x 2.5 mm² and 3x 6 mm², stranded copper conductors in a 3.5 metre conduit run incorporating one bend

16mm conduit

25mm conduit

20mm conduit

32mm conduit

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum separation distance between mains cables and communication cables?

25mm

100mm

50mm

75mm

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of cable is used on a fire alarm system, where operation in a fire is required for a prolonged period?

SWA

Butyl rubber

Glass fibre insulated

MICC

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When applying DIVERSITY to a water heater in a small shop, identify the percentage of total current demand allowed if the heater is thermostatically controlled

Not allowed

90%

75%

66%

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which hand tool should be used to install a dry lining box?

Pad saw

Pull saw

Coping saw

Tenon saw

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the maximum spacing for the supports for a 63mm diameter pvc conduit when installed in a horizontal position

2.25 metres

1.25 metres

2 metres

1.75 metres

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A steel tape is better than a steel ruler for measuring long lengths of trunking because

Steel tapes have metric measurements, while steel rulers have feet and inches

A steel tape is much more accurate than a steel ruler, and will give a closer value than a steel tape

A steel tape is easier to carry around as it fits neatly in a pocket, while a steel ruler can fall out and get lost

A steel ruler is too short, so several measurements will have to be made to find the total length

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?