Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Professional Development

28 Qs

quiz-placeholder

Similar activities

Introduction to Electronics Quiz - 1

Introduction to Electronics Quiz - 1

Professional Development

23 Qs

ELECTRICIAN 5TH TEST

ELECTRICIAN 5TH TEST

Professional Development

25 Qs

Chapter 13: Basics of Electricity

Chapter 13: Basics of Electricity

9th Grade - Professional Development

30 Qs

Automotive Electrics level 3

Automotive Electrics level 3

11th Grade - Professional Development

32 Qs

204.1

204.1

Professional Development

24 Qs

 Final revalida de ayudante de perito electricista

Final revalida de ayudante de perito electricista

Professional Development

23 Qs

Synthèse éclairage simple et va et vient

Synthèse éclairage simple et va et vient

Professional Development

25 Qs

RME_Chapter 5

RME_Chapter 5

Professional Development

30 Qs

Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Assessment

Quiz

Other

Professional Development

Hard

Created by

Amir Karbassi

Used 1+ times

FREE Resource

28 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Determine the minimum conduit size to accommodate 3 x 2.5 mm² and 3x 6 mm², stranded copper conductors in a 3.5 metre conduit run incorporating one bend

16mm conduit

25mm conduit

20mm conduit

32mm conduit

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum separation distance between mains cables and communication cables?

25mm

100mm

50mm

75mm

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of cable is used on a fire alarm system, where operation in a fire is required for a prolonged period?

SWA

Butyl rubber

Glass fibre insulated

MICC

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When applying DIVERSITY to a water heater in a small shop, identify the percentage of total current demand allowed if the heater is thermostatically controlled

Not allowed

90%

75%

66%

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which hand tool should be used to install a dry lining box?

Pad saw

Pull saw

Coping saw

Tenon saw

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the maximum spacing for the supports for a 63mm diameter pvc conduit when installed in a horizontal position

2.25 metres

1.25 metres

2 metres

1.75 metres

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A steel tape is better than a steel ruler for measuring long lengths of trunking because

Steel tapes have metric measurements, while steel rulers have feet and inches

A steel tape is much more accurate than a steel ruler, and will give a closer value than a steel tape

A steel tape is easier to carry around as it fits neatly in a pocket, while a steel ruler can fall out and get lost

A steel ruler is too short, so several measurements will have to be made to find the total length