Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Professional Development

28 Qs

quiz-placeholder

Similar activities

RME_Chapter 7

RME_Chapter 7

Professional Development

30 Qs

Mario kart Wii courses

Mario kart Wii courses

Professional Development

32 Qs

cars 3

cars 3

KG - Professional Development

25 Qs

EC8351 Electronic Circuits I

EC8351 Electronic Circuits I

Professional Development

25 Qs

Digital electronics CP15

Digital electronics CP15

Professional Development

23 Qs

ICIT: Revision (Fire Alarm)

ICIT: Revision (Fire Alarm)

Professional Development

30 Qs

Special Logic Circuits

Special Logic Circuits

10th Grade - Professional Development

26 Qs

HVAC Random 25-01

HVAC Random 25-01

Professional Development

25 Qs

Oversee & Design Mock Paper 3

Oversee & Design Mock Paper 3

Assessment

Quiz

Other

Professional Development

Hard

Created by

Amir Karbassi

Used 1+ times

FREE Resource

28 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Determine the minimum conduit size to accommodate 3 x 2.5 mm² and 3x 6 mm², stranded copper conductors in a 3.5 metre conduit run incorporating one bend

16mm conduit

25mm conduit

20mm conduit

32mm conduit

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum separation distance between mains cables and communication cables?

25mm

100mm

50mm

75mm

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of cable is used on a fire alarm system, where operation in a fire is required for a prolonged period?

SWA

Butyl rubber

Glass fibre insulated

MICC

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When applying DIVERSITY to a water heater in a small shop, identify the percentage of total current demand allowed if the heater is thermostatically controlled

Not allowed

90%

75%

66%

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which hand tool should be used to install a dry lining box?

Pad saw

Pull saw

Coping saw

Tenon saw

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the maximum spacing for the supports for a 63mm diameter pvc conduit when installed in a horizontal position

2.25 metres

1.25 metres

2 metres

1.75 metres

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A steel tape is better than a steel ruler for measuring long lengths of trunking because

Steel tapes have metric measurements, while steel rulers have feet and inches

A steel tape is much more accurate than a steel ruler, and will give a closer value than a steel tape

A steel tape is easier to carry around as it fits neatly in a pocket, while a steel ruler can fall out and get lost

A steel ruler is too short, so several measurements will have to be made to find the total length