C2 Hydrogenation reactor

C2 Hydrogenation reactor

Professional Development

11 Qs

quiz-placeholder

Similar activities

Tool & Die Maker (Dies & Moulds) Test 05

Tool & Die Maker (Dies & Moulds) Test 05

Professional Development

10 Qs

Welding

Welding

Professional Development

11 Qs

Roblox

Roblox

Professional Development

10 Qs

02 Direction of the Earth

02 Direction of the Earth

Professional Development

14 Qs

CDL Sec 2.1 - Pre-Trip

CDL Sec 2.1 - Pre-Trip

Professional Development

11 Qs

CDL Sec 2.1 - Pre-Trip

CDL Sec 2.1 - Pre-Trip

Professional Development

9 Qs

Srinagar Factory - Mechanics and Fitter

Srinagar Factory - Mechanics and Fitter

Professional Development

10 Qs

Connections Unit 10

Connections Unit 10

Professional Development

14 Qs

C2 Hydrogenation reactor

C2 Hydrogenation reactor

Assessment

Quiz

Professional Development

Professional Development

Easy

Created by

Amin Syahid

Used 2+ times

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Below is the purpose of C2 hydrogenation reactors, except..

to hydrogenate acetylene to ethylene and ethane.

To remove acetylene which is poison to polymerization reaction

The process also hydrogenates some methylacetylene and propadiene to propylene and hydrogenates butadiene to butenes

To remove moisture at cracked gas

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Hydrogenation reaction in reactor R-360 is exothermic. True or False

True

False

No comment

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Excessive N2 cause temperature R-360 to increase. True or false

True

False

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What happen if acetylene breakthrough R-360?

Product increase.

C2 product Ethylene off spec

Nothing happen

Trigger SD-3

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is CYCLE TIMES of catalyst R-360?

5-6 years

10 years

13-15 years

we can use until forever

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the type of catalyst used in R-360 NC-1?

mol sieve

Nickel based

Palladum based

Sugar based

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under what condition will R-360 will trigger SD-2?

Temperature reactor less than 200degC

Excessive DMDS in Cracked gas

Temperature cracked gas in the coil outlet 1000 degC

Temperature reactor more than 200degC

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?