Inspection and Testing Quiz

Inspection and Testing Quiz

Vocational training

10 Qs

quiz-placeholder

Similar activities

Q1- EET(N2A-N2B)

Q1- EET(N2A-N2B)

University

11 Qs

Basic Concept of Electricity and Electronics

Basic Concept of Electricity and Electronics

6th Grade

10 Qs

electrics

electrics

3rd Grade

10 Qs

KUIZ 2- ALTERNATIVE FUEL DMD 4132

KUIZ 2- ALTERNATIVE FUEL DMD 4132

University

15 Qs

18th Edition Part 6 Mock 3

18th Edition Part 6 Mock 3

Professional Development

10 Qs

DET10013 RE-CAP CHAPTER 1 PART 1

DET10013 RE-CAP CHAPTER 1 PART 1

University

10 Qs

GRADE 10 -Technology and Livelihood Education

GRADE 10 -Technology and Livelihood Education

10th Grade

15 Qs

Weeks 8 9 10

Weeks 8 9 10

University

10 Qs

Inspection and Testing Quiz

Inspection and Testing Quiz

Assessment

Quiz

Other

Vocational training

Hard

Created by

Costagis Yianni

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a certificate is issued for Initial Verification purposes, for the certificate to be valid it MUST be accompanied by?

schedules of inspections and test results

Part 'P' certificate

inspection tick-sheet

test results sheet

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the installation of a new circuit to an existing installation has been completed, the inspector will issue?

a schedule of the tests completed

a condition report

a minor-works certificate

an initial verification certificate

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical installation certificate for a new installation will require THREE signatories, Identify one of these signatories.

the owner

the site manager

the designer

the local authority

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the human senses would be used to determine that a BS3036 device has operated?

hearing

touch

smell

sight

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the indication to be used on an Initial Verification Schedule of Inspection form to indicate that an item meets the requirements of BS7671

Lim

a cross (x)

a tick

N/A

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Supplementary bonding conductors that are protected against mechanical damage shall have a CSA no smaller than?

10 sqmm

6 sqmm

4 sqmm

2.5 sqmm

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

State the effect of running a separate copper conductor connected at each end in parallel with the steel-wire-armour of a SWA, for its entire length.

overall (R1+R2) value for the circuit would increase

disconnection times would increase

there would be no effect

overall (R1+R2) value for the circuit would decrease