CW - Mechanical Backflow Prevention Arrangements PP10

CW - Mechanical Backflow Prevention Arrangements PP10

University

10 Qs

quiz-placeholder

Similar activities

SPECIAL CONTROL VALVES

SPECIAL CONTROL VALVES

University

15 Qs

INTRODUCTION TO INTERNAL COMBUSTION

INTRODUCTION TO INTERNAL COMBUSTION

1st Grade - University

10 Qs

Piping Post Test

Piping Post Test

University - Professional Development

10 Qs

CW - Fluid Categories Quiz PP8

CW - Fluid Categories Quiz PP8

University

12 Qs

Hot Water 3

Hot Water 3

University

15 Qs

Plumbing & HVAC

Plumbing & HVAC

11th Grade - University

10 Qs

AMT 11-08 Quiz no. 2

AMT 11-08 Quiz no. 2

University

10 Qs

Kapal Khusus (last meeting)

Kapal Khusus (last meeting)

University

10 Qs

CW - Mechanical Backflow Prevention Arrangements PP10

CW - Mechanical Backflow Prevention Arrangements PP10

Assessment

Quiz

Other

University

Medium

Created by

Eden Longley

Used 6+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the fluid category protection rating for a "Non-verifiable disconnector with difference between pressure zones not greater than 10%" against back-pressure?

4

3

2

X

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of heating system is mentioned in the context of using a type CA backflow preventer?

Open central heating system

Sealed central heating system

Electric heating system

Gas heating system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What type of system is shown in the diagram?

Electrical system

Gas system

Central heating system

Air conditioning system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On which devices must DB pipe interrupters not be used?

Hose union bib taps

Water heaters

Devices with a control valve restriction

Garden hoses

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How must DB pipe interrupters be fitted?

Horizontally

Vertically

At an angle

Upside down

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must not be installed downstream of DB pipe interrupters?

Control valves

Hose union bib taps

Water heaters

Valves

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To which standard does the EA single check valve conform?

BS6282 Part 2

BS6282 Part 1

BS6283 Part 1

BS6283 Part 2

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?