4-6 Morgan KC

4-6 Morgan KC

Professional Development

10 Qs

quiz-placeholder

Similar activities

simbol chemical

simbol chemical

Professional Development

7 Qs

Examen de Alerta Roja

Examen de Alerta Roja

Professional Development

12 Qs

Breathing Circuits Quiz

Breathing Circuits Quiz

Professional Development

14 Qs

Current Affairs and Science Quiz

Current Affairs and Science Quiz

Professional Development

15 Qs

POST TEST

POST TEST

Professional Development

5 Qs

photosynthensis

photosynthensis

Professional Development

5 Qs

BSLs and Symbols

BSLs and Symbols

Professional Development

14 Qs

Review - GTE Ganjil 12AP 24/25

Review - GTE Ganjil 12AP 24/25

Professional Development

10 Qs

4-6 Morgan KC

4-6 Morgan KC

Assessment

Quiz

Others

Professional Development

Medium

Created by

dr. Mahenta

Used 3+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the most prevalent cause of equipment-related adverse outcomes according to closed claims?

Device malfunction

Misuse of anesthesia gas delivery systems

Improper calibration

Lack of oxygen supply

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the mechanical ventilator in the anesthesia machine?

To control the flow of medical gases

To deliver gases to the patient's airway

To vaporize anesthetics

To reduce the pressure of gases

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What safety feature of anesthesia machines helps ensure a minimum oxygen concentration of 25%?

Double-circuit system design

Pressure sensors for oxygen monitoring

Automatic shutdown in case of oxygen failure

Linkage of nitrous oxide gas flow to oxygen gas flow

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the advantage of a piston ventilator in anesthesia machines?

Enhanced temperature control

Improved oxygen concentration

Reduced risk of gas leaks

Ability to deliver accurate tidal volumes

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be avoided when using the oxygen flush valve during the inspiratory cycle of a ventilator?

Closing the ventilator spill valve

Decreasing the circuit pressure

Increasing the fresh gas flow

Opening the APL valve

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a common cause of large discrepancies between set and actual tidal volume during volume-controlled ventilation?

Breathing circuit compliance

Patient's lung compliance

Gas compression

Ventilator peak airway pressure limit

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of waste-gas scavengers in anesthesia equipment?

To dispose of excess anesthetic gases

To monitor patient CO levels

To regulate oxygen flow

To prevent circuit leaks

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?