Unit 29 review

Unit 29 review

University

14 Qs

quiz-placeholder

Similar activities

How does a Refrigerator work

How does a Refrigerator work

University

14 Qs

RAC quiz_ankit saxena

RAC quiz_ankit saxena

University

16 Qs

IXL 5th Grade C1, C2, & C3

IXL 5th Grade C1, C2, & C3

5th Grade - University

12 Qs

Refrigeration Cycle

Refrigeration Cycle

University

15 Qs

Thermo Actual, Reheat, and Regen Review - Multiple Choice

Thermo Actual, Reheat, and Regen Review - Multiple Choice

University

13 Qs

COMBINED CYCLE

COMBINED CYCLE

University

10 Qs

Refrigeration Cycle

Refrigeration Cycle

University

15 Qs

HVAC Quiz

HVAC Quiz

12th Grade - University

15 Qs

Unit 29 review

Unit 29 review

Assessment

Quiz

Science

University

Medium

Created by

Robert Hemmila

Used 1+ times

FREE Resource

14 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerated cabinet temperature of a high-temperature refrigeration unit ranges from ____.

25°F to 45°F

45°F to 60°F

60°F to 75°F

75°F to 95°F

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a high-temperature refrigeration unit, the boiling point of the refrigerant in the coil is normally ____ lower than the cabinet temperature.

5°F to 15°F

10°F to 20°F

25°F to 35°F

35°F to 46°F

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medium-temperature refrigerated cabinet temperatures range from ____.

5°F to 20°F

20°F to 35°F

30°F to 45°F

35°F to 50°F

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The process of ice making usually occurs in which temperature range?

-10°F to 0°F

0°F to 5°F

5°F to 20°F

20°F to 30°F

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Condensing units located outside that are required to operate year-round must have ____.

EPR valves

head pressure control

all weather protection

large fan motors

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With the entering air to the condenser above 70°F, the temperature difference between the outdoor air and the condensing temperature on standard units will be ____.

10°F to 15°F

15°F to 20°F

20°F to 25°F

25°F to 30°F

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a wastewater system, the water entering the condenser is 85°F and the water leaving the condenser is 105°F. Which of the following statements is a logical explanation for the above conditions?

reduced water flow through the condenser

scale buildup in the water circuit

excess water flow through the condenser

both a and b