Phase4.mod13.chimney test

Phase4.mod13.chimney test

Professional Development

7 Qs

quiz-placeholder

Similar activities

Rosukem / Rosukem-EZ

Rosukem / Rosukem-EZ

Professional Development

10 Qs

Trivia

Trivia

11th Grade - Professional Development

10 Qs

Quiz Game

Quiz Game

KG - Professional Development

12 Qs

GranMonte Master Class

GranMonte Master Class

Professional Development

10 Qs

CURRENT AFFAIRS

CURRENT AFFAIRS

12th Grade - Professional Development

10 Qs

Vitalis Integra - Erudite 2.0 Live Quiz - April 2024

Vitalis Integra - Erudite 2.0 Live Quiz - April 2024

Professional Development

10 Qs

Eclipses

Eclipses

KG - Professional Development

11 Qs

QUIZ SAFETY SEMINAR ROADSHOW

QUIZ SAFETY SEMINAR ROADSHOW

Professional Development

12 Qs

Phase4.mod13.chimney test

Phase4.mod13.chimney test

Assessment

Quiz

Science

Professional Development

Practice Problem

Medium

Created by

Craig Boothright

Used 3+ times

FREE Resource

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If there is an extractor fan fitted in an adjacent room to where a spillage test is being performed, the gas operative must:

Turn the fan on and open the adjoining door.

Turn on the fan and close the adjoining door.

Turn the fan off and open the adjoining door.

Turn off the fan and close the adjoining door.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The gas operative need only carry out a spillage test when installing an appliance:

True.

False.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A Flue Flow test must be carried out using a smoke pellet and the appliance.

Turned off.

Turned on low rate.

Turned on full rate.

It may be either on or off.

4.

FILL IN THE BLANK QUESTION

1 min • 1 pt

When carrying out a spillage test the doors, windows and any adjustable vents in the appliance room must be:

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If during the flue flow test the gas operative observes smoke exiting the flue into an upstairs room, the action to be taken must be to:

Treat as Immediately Dangerous.

Treat as At Risk.

Treat as Not to current standards.

Inform Gas Safe Register.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A spillage Test must be carried out using a smoke match or taper with the appliance:

Turned off.

Turned on low rate.

Turned on full rate.

It may be either on or off.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a spillage test is carried out on an open flued boiler , The smoke match holder must be placed near the:

Burner.

Draught diverter.

Combustion air inlet.

Convection air inlet.