EE 030 S2

EE 030 S2

Professional Development

10 Qs

quiz-placeholder

Similar activities

Endpoint Protection and Firewall Config

Endpoint Protection and Firewall Config

Professional Development

5 Qs

3. Introduction to Power Supply Installations

3. Introduction to Power Supply Installations

Professional Development

15 Qs

Emissions Control Systems Quiz

Emissions Control Systems Quiz

Professional Development

10 Qs

Directory Services

Directory Services

Professional Development

12 Qs

AC Circuits Quiz

AC Circuits Quiz

Professional Development

9 Qs

Intro to Carbon Footprint Assessment

Intro to Carbon Footprint Assessment

Professional Development

7 Qs

Quiz on Security Patches and Updates

Quiz on Security Patches and Updates

Professional Development

6 Qs

Breadboards Quiz

Breadboards Quiz

Professional Development

6 Qs

EE 030 S2

EE 030 S2

Assessment

Quiz

Engineering

Professional Development

Practice Problem

Medium

Created by

S B

Used 12+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A single piece of equipment consisting of a multiple receptacle comprised of four or more receptacles shall be calculated at not less than __ volt-amperes per receptacle.

180

90

230

100

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

General Lighting Loads by Occupancy: For dwelling units, the VA/sqm is ____?

24

32

8

16

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Lighting outlets shall be permitted to be controlled by occupancy sensors that are (1) in addition to wall switches or (2) located at a customary wall switch location and equipped with a manual override that will allow the sensor to function as a wall switch.

True

False

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Wall Space: Any space ___ mm or more in width (including space measured around comers) and unbroken along the floor line by doorways and similar openings, fireplaces, and fixed cabinets that do not have countertops or similar work surfaces.

3600

1800

600

1200

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Single Branch Circuit. For dwelling unit having a floor area not more than 50 sq.m. it shall be permitted to have single 20-ampere 2-wire branch-circuit provided that the total load shall not exceed 3680 volt-amperes.

True

False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Kitchen Dishwasher Branch Circuit: ______protection shall be provided for outlets that supply dishwashers installed in dwelling unit locations.

Grounding

AFCI

GFCI

OCPD

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Doors. Each doorway leading into a vault from the building interior shall be provided with a tight-fitting door that has a minimum fire rating of ____ hours.

2

3

4

5

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?