Unsafe Situations (Examples) GIUSP

Quiz
•
Science
•
Professional Development
•
Medium
Rob Anderson
Used 10+ times
FREE Resource
12 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
3.3 In an emergency situation (e.g. gas escaping) where there is restricted access or there is not a handle fitted to ECV (AR)
3.10 Pipework suitable for gas used in an inappropriate location and/or situation (AR)
3.11 Pipework showing significant signs of damage from corrosion or mechanical damage (AR)
3.12 Gas pipework located within a cavity wall or void but not within a purpose made duct (AR)
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
8.8 Unsupported flue system (AR)
8.8 Unsupported flue system (AR) & 6.2 Leakage of products of combustion (ID)
6.5 No means of examining a room sealed concealed flue system (AR)
6.5 No means of examining a room sealed concealed flue system (AR) & 6.2 Leakage of products of combustion (ID)
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
1.4 Flueless appliances: evidence of poor combustion occurring (ID)
6.2 Leakage of products of combustion from room sealed chimney system (ID)
Flueless appliance with visual signs of incomplete combustion (ID)
1.4 Flueless appliances: evidence of poor combustion occurring (ID) & Flueless appliance with visual signs of incomplete combustion (ID)
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
3.1 Pipework with an open end connected to a gas supply (ID)
3.2 Pipework and/or fittings of inappropriate material for purpose (ID) also RIDDOR reportable
3.6 Undersized pipework proved to be affecting the safe operation if any appliance (ID)
3.10 Pipework suitable for gas used in inappropriate location and/or situation (AR)
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
2.4 Medium pressure or higher pressure fed regulator relief valve and/or vent pipe discharging in an unsafe location (ID)
2.5 Meter and/or regulator showing significant signs of damage (AR)
2.8 Pathway for gas to enter property from meter box (AR)
3.5 In an non-emergency situation where there is restricted access or there is not a handle fitted to ECV
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
3.10 Pipework suitable for gas used in an inappropriate location and/or situation (AR)
3.11 pipework showing significant signs of damage from corrosion or mechanical damage (AR)
3.13 Gas pipework located within a cavity wall or void not within a purpose provided duct (AR)
3.4 Undersized pipework proved to be affecting the safe operation of any appliance (ID)
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Why was the gas supply re-routed? Is this installation acceptable?
Yes, since the old supply is capped off and meter box knock out sealed this installation now complies with GSIUR and GIUSP
No, although the gas supply has been re-routed the PEB still enters the property (in accordance with 2.10 (AR))
The rear of the meter box is still compromised (AR)
Create a free account and access millions of resources
Similar Resources on Wayground
12 questions
Meteorologia para CMS - parte 3

Quiz
•
1st Grade - Professio...
12 questions
Internship Day 3

Quiz
•
Professional Development
12 questions
Phase 4 mod3

Quiz
•
Professional Development
11 questions
ACS Quiz 2

Quiz
•
Professional Development
10 questions
LABORATORY ELEMENTS.

Quiz
•
Professional Development
15 questions
Gas Installation and Tightness Test Quiz

Quiz
•
Professional Development
14 questions
phase4,mod12.chimney

Quiz
•
Professional Development
15 questions
Sains Tingkatan 2 Bab 5 Air dan Larutan

Quiz
•
Professional Development
Popular Resources on Wayground
50 questions
Trivia 7/25

Quiz
•
12th Grade
11 questions
Standard Response Protocol

Quiz
•
6th - 8th Grade
11 questions
Negative Exponents

Quiz
•
7th - 8th Grade
12 questions
Exponent Expressions

Quiz
•
6th Grade
4 questions
Exit Ticket 7/29

Quiz
•
8th Grade
20 questions
Subject-Verb Agreement

Quiz
•
9th Grade
20 questions
One Step Equations All Operations

Quiz
•
6th - 7th Grade
18 questions
"A Quilt of a Country"

Quiz
•
9th Grade