Refrigerant Piping Techniques 3-2

Refrigerant Piping Techniques 3-2

12th Grade

15 Qs

quiz-placeholder

Similar activities

Defrosting Circuits and Controls Quiz

Defrosting Circuits and Controls Quiz

12th Grade

15 Qs

Refrigeration Systems Quiz

Refrigeration Systems Quiz

12th Grade

10 Qs

Air Conditioning Components

Air Conditioning Components

10th - 12th Grade

10 Qs

Piping Design and Installation 3-3

Piping Design and Installation 3-3

12th Grade

14 Qs

Refrigeration Systems Quiz

Refrigeration Systems Quiz

12th Grade

14 Qs

The Heatpump

The Heatpump

12th Grade

10 Qs

Defrosting Methods Quiz pt1

Defrosting Methods Quiz pt1

12th Grade

10 Qs

Stair Construction

Stair Construction

9th - 12th Grade

10 Qs

Refrigerant Piping Techniques 3-2

Refrigerant Piping Techniques 3-2

Assessment

Quiz

Specialty

12th Grade

Medium

Created by

Andgel Thomas

Used 1+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary goal of maintaining proper refrigerant feed to the evaporators?

To enhance compressor noise

To reduce energy consumption

To ensure correct refrigerant quantity

To minimize installation costs

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended oil return pitch for a horizontal line?

3/4" per 10 ft

1/2" per 10 ft

1" per 10 ft

1/4" per 10 ft

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum velocity required to maintain refrigerant flow in a vertical suction riser?

1000 fpm

1500 fpm

2000 fpm

2500 fpm

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of an inverted trap in a suction riser?

To reduce noise levels

To prevent oil and refrigerant from flowing back

To increase refrigerant pressure

To enhance heat transfer

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a double suction riser, what is the purpose of the smaller line?

To manage part load conditions

To reduce oil return

To handle full load capacity

To increase pressure drop

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of multiple evaporator traps?

To increase pressure drop

To eliminate compressor cycling

To reduce refrigerant flow

To maintain proper oil return

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main concern with the discharge riser?

Pressure drop

Noise pulsations

High temperature

Excessive oil return

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?