ACR-206 Chapter 59 Test (CRF)

ACR-206 Chapter 59 Test (CRF)

University

20 Qs

quiz-placeholder

Similar activities

DSL-206 Chap 17: Heavy Duty Starting Systems and Circuits

DSL-206 Chap 17: Heavy Duty Starting Systems and Circuits

University

15 Qs

Chapter 51 Drum Brakes Test Review

Chapter 51 Drum Brakes Test Review

University

15 Qs

SOAL AC SPLIT

SOAL AC SPLIT

11th Grade - University

15 Qs

Engine Mechanical Assessment 1

Engine Mechanical Assessment 1

9th Grade - University

20 Qs

ENGINE COOLING SYSTEM ASSESSMENT

ENGINE COOLING SYSTEM ASSESSMENT

9th Grade - University

20 Qs

HAC-101 Chap 58 Principles of HVAC Test A

HAC-101 Chap 58 Principles of HVAC Test A

University

20 Qs

#1 EPA 608 CORE

#1 EPA 608 CORE

11th Grade - University

25 Qs

ASE A5 Brake System Quiz 2

ASE A5 Brake System Quiz 2

10th Grade - University

20 Qs

ACR-206 Chapter 59 Test (CRF)

ACR-206 Chapter 59 Test (CRF)

Assessment

Quiz

Other

University

Hard

Created by

Joshua LeValley

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The __________ typically disables the A/C system if pressures fall below 10 psi (69 kPa).

Low-pressure switch

TXV (thermal expansion valve)

Heater control

High-pressure relief

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the most common source of abnormal noises arising from the air conditioner?

Evaporator

Compressor

Accumulator

Muffler

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the first step in the diagnostic process for air-conditioning systems?

System pressure test

Diagnosis of faults

Performance testing

Check for codes in the computer

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A __________ is connected to the air-conditioning refrigerant ports before the performance test begins.

Thermometer

Manifold pressure gauge set

Micron gauge

Safety switch

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following works very well for testing discharged systems or for pre-checking for a leak after repairs have been made and before recharging the system?

Fluorescent dye

Oxygen

Compressed Air

Nitrogen

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a method of leak testing? Select one:

Vacuum testing

Electronic leak detection

Dye testing

Nitrogen testing

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Flushing with __________ may be necessary for some components, as this removes moisture-laden oil and some contaminated oil. Select one:

Nitrogen

Compressed air

Refrigerant gas

Lubrication oil

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?