Search Header Logo

Natural Gas Distribution Network Quiz

Authored by Steven Endicott

Education

12th Grade

57 Questions

Natural Gas Distribution Network Quiz
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of pressure regulation in a natural gas distribution network?

Close the supply.

Ensure safe delivery.

Prevent gas leaks.

Open the supply.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a pressure regulator fitted on the inlet to a primary gas meter?

To maintain a defined pressure to a system, by adjusting the flow of gas.

To adjust the pressure so that it meets the needs of the system design.

To maintain and monitor pressure to a system, by cutting off the gas flow in an emergency.

To remove pressure and prevent damage to the system in an emergency.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the most likely cause of pressure loss when carrying out a tightness test?

An overrated gas appliance on the system.

The regulator letting by during the test period.

A gas escape somewhere on the system.

The ECV letting by during the test period.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which statement correctly describes how a dangerous occurrence could happen during the combustion process?

Incomplete combustion due to insufficient oxygen, which results in carbon monoxide.

Incomplete combustion due to excessive oxygen, which results in carbon monoxide.

Incomplete combustion due to insufficient oxygen, which results in carbon dioxide.

Incomplete combustion due to excessive oxygen, which results in carbon dioxide.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How is evidence of incomplete combustion on a gas appliance identified?

A blue flame is present.

The appliance is hot to touch.

Noisy burner when in operation.

Soot deposits around the appliance.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the required activation time for a carbon monoxide alarm, when exposed to a concentration of 100 ppm?

Between 10 minutes and 40 minutes

Within 10 minutes

Between 45 minutes and 60 minutes

After 60 minutes

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A new hair salon has recently opened. A carbon monoxide detector in the salon is being activated intermittently during business hours. A new room-sealed appliance was recently installed on the premises; a gas-safe engineer has confirmed that the appliance is in good working order. What is the cause of this issue?

Heat produced by electrical panel heaters.

Aerosol products used on hair.

Warm air currents from hair dryers.

Bright lighting used during business hours.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?