1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

During engine start:

The extract fan stops during 120 seconds, and the EXHAUST MODE pushbutton FAULT light illuminates.

Extract fan stops during 60 seconds, and the EXHAUST MODE pushbutton FAULT light does not illuminate.

The extract fan stops during 10 seconds.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How high above take off elevation can the aircraft be operated without canceling the automatic return feature?

any altitude 3,500 feet above the landing field elevation

2,500 feet on QNE (1013)

any altitude less than 3,500 feet above the departure field elevation

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The functions of the pack valve are:

shut off and pressure control

shut off, pressure control, and temperature control

pressure control only

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The pneumatic outflow valve:

is slaved to the electro-pneumatic outflow valve in the automatic mode only

operates in the manual mode only

is always slaved to the electro-pneumatic outflow valve

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The temperature control valve is:

The valve is controlled in the automatic mode by the electronic temperature controller. In the manual mode, it is controlled by the compartment temperature selector knob.

The valve is controlled in the automatic mode by the RECIRC FAN pushbutton. In the manual mode, it is controlled by the electronic temperature controller.

The valve is controlled in the automatic mode by the pneumatic temperature controller. In the manual mode, it is controlled by the compartment temperature selector knob.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

During normal operations with no failures, the pressurization controller uses as reference the aircraft static air pressure generated by:

ADC 1 and the Captain's altimeter BARO setting

ADC 2 and the Captain's altimeter BARO setting

ADC 1 and 1013 hPa

ADC 2 and 1013 hPa

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The compartment temperature selector knob is operative:

in the automatic mode only

in the automatic and manual modes

in the manual mode only

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?