1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A common practice in condensing units is to use a contactor with only one set of contacts opening only one side of the power to the unit. This is to ____.

reduce the cost of the contactor

provide off-cycle heat to the compressor

make it easier to wire the unit

teach the service technician not to put hands in the unit with the power on

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Beside maintaining pressure on the contacts for current carrying capacity, the pressure springs have a second important function. This is to ____.

help obtain equal contacts against the stationary contacts

increase the power required to close the contacts

slow down the pull of the armature into place to reduce the noise

keep the contacts in line

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a contactor's coil is energized, how much resistance should be measured between terminal "L1" and terminal "T1"?

infinite

50-3000 ohms

5000-6000 ohms

zero ohms

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Technician “A” says that if you take a voltage reading from terminal "L1" to terminal "T1" on a contactor whose coil is energized, you should read zero volts. Technician “B” says that contactors can only have normally open contacts. Which of the following statements is correct?

Technician "A" is correct. Technician "B" is correct.

Technician "A" is incorrect. Technician "B" is incorrect.

Technician "A" is correct. Technician "B" is incorrect.

Technician "A" is incorrect. Technician "B" is correct.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An inherent motor protector is a ____.

line fuse

circuit breaker

thermally activated device in the motor winding

motor starter overload

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The service factor of an electric motor is determined by ____.

the required wire size supplying power to the motor

National Electrical Code

motor's reserve capacity

the required wire size supplying power to the motor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Standards for motor overload protection are set by the ____.

American National Standards Institute

Environmental Protection Agency

National Electrical Code

Environmental Protection Agency

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?