Electrical Systems Quiz 3-

Electrical Systems Quiz 3-

22 Qs

quiz-placeholder

Similar activities

Conductors and Insulators

Conductors and Insulators

KG - University

21 Qs

Brake faults

Brake faults

KG - University

20 Qs

INGENIERÍA DE REDES 1-4

INGENIERÍA DE REDES 1-4

KG - University

25 Qs

We Build It Better: Kit 5 Pre-Assessment

We Build It Better: Kit 5 Pre-Assessment

KG - University

21 Qs

FOT Post-Test - Microbit:

FOT Post-Test - Microbit:

8th Grade

27 Qs

Module 4 Science Test Review

Module 4 Science Test Review

3rd Grade

20 Qs

Electricity and Circuits

Electricity and Circuits

KG - University

19 Qs

Electrical Systems Quiz 3-

Electrical Systems Quiz 3-

Assessment

Quiz

others

Medium

Created by

Richard Hodgett

Used 9+ times

FREE Resource

22 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following documents covers the installation and design requirements of a basic domestic type electrical circuit
a) BS7671
b) BS6700
c) BS5449
d) BS EN 12056

2.

MULTIPLE CHOICE QUESTION

30 sec • Ungraded

Which one of the following is the most likely supply voltage type and rating used for an immersion heater within a hot water cylinder
a) 110v ac
b) 24v dc

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following voltages would be found on a low voltage central heating wiring system
a) 12v dc
b) 24v ac
c) 110v dc
d) 110v ac

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of domestic electric circuit would you use to connect an immersion heater to.
a) spur
b) lighting circuit
c) radial
d) ring main

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following earthing arrangements uses an installation earth electrode as part of the earth fault path
a) TN-C
b) TN – C – S
c) TT
d) TN-S

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

which one of the following conductors connects an installations main earthing terminal to the incoming metallic gas supply service pipe
a) CPC
b) High integrity protective conductor
c) Main protective bonding conductor
d) Supplementary bonding conductor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following conductors would normally connect the service pipes together beneath a combi boiler
a) CPC
b) High integrity protective conductor
c) Main protective bonding conductor
d) Supplementary bonding conductor