GMJ 6189 electrical quiz

GMJ 6189 electrical quiz

Vocational training

9 Qs

quiz-placeholder

Similar activities

Plumbing Assessment Test

Plumbing Assessment Test

KG - University

7 Qs

Reducing Waste

Reducing Waste

KG - University

6 Qs

Plumbing Materials: Understanding Radiator Components

Plumbing Materials: Understanding Radiator Components

KG - University

14 Qs

Plumbing Materials: Radiator Valves True or False

Plumbing Materials: Radiator Valves True or False

KG - University

8 Qs

Venting Procedure

Venting Procedure

KG - University

10 Qs

GMJ 6189-33 unit 302

GMJ 6189-33 unit 302

KG - University

12 Qs

AC 2.44 Quiz on Full-Way Gate Valves

AC 2.44 Quiz on Full-Way Gate Valves

12th Grade

10 Qs

Manual Handling in Construction

Manual Handling in Construction

KG - University

11 Qs

GMJ 6189 electrical quiz

GMJ 6189 electrical quiz

Assessment

Quiz

Construction

Vocational training

Medium

Created by

Glen Johnson

Used 3+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which device contains a bi-metal device?

MCB EN 60898

RCD

BS 88

Fuse

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Insulation test to a 230v circuit would require a test voltage of

230 v

415 v

500 v (new installs with no load)

1000v

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which is NOT part of an inspection?

All equipment is to British Standard

No signs of damage

Equipment is suitable

All parts are correctly selected

Phase rotation test

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of an earth is

Increase disconnection time

Decrease disconnection time

Provide earth fault loop impedance (path/earth)

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An existing system is to be extended, the correct procedure would be to

Continue with the installation

Re-calculate the load and compare

Re-calculate the load ensuring diversity and compare

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

You suspect an open circuit to a thermostat connected to a motorised valve. You would check the cable with a;

Low resistance ohmmeter

Volt meter

Insulation tester

Neon screw driver

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The cable that supplies a zone valve connected to the wiring centre is

4 core (I think, L, N Switched L and earth?)

5 core

6 core

7 core

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The function of an auxiliary switch in a motorised valve is

To operate system components

To protect against over current

To protect against earth leakage

To prevent over heating

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which test is not recorded on a minor works certificate?

Positive fault current at the supply origin

Total earth fault loop impedance value

Insulation resistance value

Polarity