ACR204-Unit 38 Test Questions (CRF) - Mr. Graham

ACR204-Unit 38 Test Questions (CRF) - Mr. Graham

12th Grade

10 Qs

quiz-placeholder

Similar activities

Quiz 4: Lines and Cable

Quiz 4: Lines and Cable

12th Grade - Professional Development

10 Qs

ET 26104

ET 26104

12th Grade

12 Qs

Digestion and Absorption in Human-1

Digestion and Absorption in Human-1

9th - 12th Grade

12 Qs

CHECK POINT B AMTBLK6

CHECK POINT B AMTBLK6

12th Grade

15 Qs

AES - Electrical System

AES - Electrical System

KG - Professional Development

15 Qs

Ohm's Law

Ohm's Law

9th Grade - Professional Development

14 Qs

25-04-20

25-04-20

KG - Professional Development

8 Qs

ASK Team quiz 1

ASK Team quiz 1

10th Grade - Professional Development

15 Qs

ACR204-Unit 38 Test Questions (CRF) - Mr. Graham

ACR204-Unit 38 Test Questions (CRF) - Mr. Graham

Assessment

Quiz

Professional Development

12th Grade

Hard

Created by

Randall Graham

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When connecting round metal duct sections, a minimum of ___ self-taping sheet metal screws should be used.

3

2

4

5

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The applied voltage (the voltage that the unit will actually be drawing) should be within ___% of the rated voltage of the unit.

10

7

5

3

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A disconnect or shutoff switch should be installed within ____ feet of each unit and within sight of the unit.

25

20

15

10

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

18-4 low-voltage wire is ________.

18-gauge wire with 4 conductors inside

4-gauge wire with a current rating of 18 amps

14-gauge wire with a current rating of 4 amps

18-gauge wire, 4 total allowed in ½ inch conduit

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An air conditioner in a climate with average humidity will collect about 3 pints of condensate per hour of operation for each ton of air-conditioning.

True

False

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A _______ is located in an auxiliary drain pan and is wired in series with the low voltage power supply.

float switch

pressure switch

delay timer

auxiliary thermostat

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Line sets come in standard lengths of _______.

25 feet and 50 feet

10 feet and 15 feet

15 feet and 35 feet

50 feet and 100 feet

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?