48 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum distance between the open vent and cold feed on an H-frame?

100mm

125mm

150mm

175mm

Answer explanation

The maximum distance between the open vent and cold feed on an H-frame is specified as 150mm. This ensures proper functionality and efficiency in the system, making 150mm the correct choice.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the most suitable position for the installation of an expansion vessel within a central heating system?

On the flow pipe near to the boiler

On the return pipe near to the boiler

On the cold feed pipe to the system

On the open vent pipe

Answer explanation

The expansion vessel should be installed on the return pipe near to the boiler to effectively manage pressure changes and accommodate thermal expansion, ensuring optimal system performance.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What item allows the individual control of hot water and central heating timing?

Boiler

Two port valve

Room stat

Programmer

Answer explanation

The programmer is the device that allows users to set specific times for heating and hot water, providing control over when these systems operate. This makes it the correct choice for managing heating schedules.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An S-plan system has what type of valve controlling the hot water and central heating circuits?

Three port valve

Mid position valve

Two port valves

Gravity circulation

Answer explanation

An S-plan system uses two port valves to control the flow of hot water to either the heating circuit or the hot water circuit, allowing for efficient operation without the need for a mid-position valve.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the zone valve closes, the boiler switches off and the circulator stops running, but the programmer is still on; this is known as…

Boiler interlock

Boiler cycling

Boiler overheating

Boiler lockout

Answer explanation

When the zone valve closes, it signals the boiler to stop heating, which is a function of the boiler interlock system. This ensures that the boiler and circulator only operate when needed, preventing unnecessary energy use.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Look at the image in the Question above. How is the heating system piped?

One-pipe

One-pipe reverse return

Two-pipe

Two-pipe reverse return

Answer explanation

The heating system is piped as a two-pipe system, which consists of separate pipes for supply and return of water, allowing for more efficient heating and better temperature control compared to one-pipe systems.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended maximum surface temperature for heat emitters in schools and NHS properties?

42 degrees

43 degrees

45 degrees

53 degrees

Answer explanation

The recommended maximum surface temperature for heat emitters in schools and NHS properties is 43 degrees. This limit helps ensure safety and comfort for occupants.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?