Electrical Fault-Finding on Plumbing Equipment Quiz

Electrical Fault-Finding on Plumbing Equipment Quiz

Vocational training

19 Qs

quiz-placeholder

Similar activities

Post Test !!!

Post Test !!!

University

15 Qs

Retrieval practice software development methodologies #6

Retrieval practice software development methodologies #6

KG - University

20 Qs

Check 6 Style

Check 6 Style

KG - University

18 Qs

SQA HFT Sensory Testing / Analysis

SQA HFT Sensory Testing / Analysis

KG - University

16 Qs

Grade 6 - PT1 MCQ

Grade 6 - PT1 MCQ

6th Grade

20 Qs

Pasta Exam

Pasta Exam

KG - University

20 Qs

2.3 Defensive Design

2.3 Defensive Design

KG - University

20 Qs

 Electrical Theory

Electrical Theory

KG - University

22 Qs

Electrical Fault-Finding on Plumbing Equipment Quiz

Electrical Fault-Finding on Plumbing Equipment Quiz

Assessment

Quiz

others

Vocational training

Medium

Created by

Brendan Cocks

Used 2+ times

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to the Electricity at Works Regulations 1989, what is the preferred state of electrical supplies before work begins?
Energized
Dead
Partially energized
Disconnected

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the first step in diagnosing electrical faults according to the presentation?
Visual inspection
Communication with the client
Testing components
Reviewing manufacturer’s instructions

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a recommended practice when conducting live testing?
Using approved testing equipment
Informing others in the vicinity
Using homemade test lamps
Protecting the area with barriers

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be checked first when troubleshooting a heating system's programmer?
Switched live outputs
Power supply
Thermostat operation
Zone valve status

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When testing a thermostat, what indicates that the switch is closed and calling for heat?
OL reading
High resistance
Low resistance
No reading

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a common issue with zone valves in heating systems?
They overheat
They fail to operate
They create short circuits
They are always open

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does an infinity (OL) reading indicate when testing a zone valve motor?
The motor is operational
The motor is faulty
The motor is overheating
The motor is under load

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?