1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any addition to an existing installation should:

have a similar wiring system to that used in the existing installation.

be inspected and tested separate from the existing installation.

not impair the safety of the existing installation.

have its own energy meter separate from that of the existing installation.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following duties is ‘not’ the responsibility of the inspector?

to carry out maintenance and repairs on the installation.

to compare the test results with the design criteria.

to advise on remedial works.

to recommend the immediate isolation of defective parts.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Inspection of a fully enclosed domestic consumer unit would not need verification for:

identification of conductors.

rating and type of protective devices.

insulation resistance between live conductors and earth.

correct connection of single-pole devices.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Before commencing live tests and before energizing the installation, it is vital that you:

Inform other people in the area.

Disconnect the earth conductor from the Main Earth Terminal.

Evacuate the area of the general public.

Erect barriers around the testing area.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A room in which there is a 13 A socket outlet is to be converted into a bathroom. The socket outlet must be:

removed from the room.

moved to become a ceiling socket outlet.

fitted with a switch.

moved so as to be more than 3 m from the bath.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where vertical trunking passes through floors internal fire resistant barriers must be:

at maximum intervals of 3 m.

only at the top of the trunking.

at each floor level.

mid-way between each floor.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Electrical test probes must comply with standards set by:

BS 7671.

GN 3.

Guidance Note GS 38.

BS EN 60598.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Discover more resources for Education