Cistern Installation Quiz

Cistern Installation Quiz

Vocational training

10 Qs

quiz-placeholder

Similar activities

307 Central Heating Systems 3 Quiz

307 Central Heating Systems 3 Quiz

2nd Grade - University

10 Qs

CIVL372_Quiz 1

CIVL372_Quiz 1

University

10 Qs

308 Rainwater Systems 1 Quiz

308 Rainwater Systems 1 Quiz

2nd Grade - University

7 Qs

GMJ 6189-33 unit 302

GMJ 6189-33 unit 302

KG - University

12 Qs

PPT 3 - Pipework & Circulation COL

PPT 3 - Pipework & Circulation COL

12th Grade - University

15 Qs

Bowl Urinal System Quiz

Bowl Urinal System Quiz

12th Grade

15 Qs

214 ppt 1 Water Supply and Management Quiz

214 ppt 1 Water Supply and Management Quiz

12th Grade

15 Qs

isolating and switching quiz

isolating and switching quiz

KG - University

10 Qs

Cistern Installation Quiz

Cistern Installation Quiz

Assessment

Quiz

Construction

Vocational training

Hard

Created by

Paul Ward

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum capacity of a cold-water cistern for a small house as per BS EN 806?

50–100 litres

100–150 litres

150–200 litres

200–250 litres

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should the float-operated valve (inlet) be positioned in relation to the outlet to avoid stagnation?

Above the outlet

Below the outlet

Opposite the outlet

Next to the outlet

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What standard must the float-operated valve comply with?

BS 1205

BS 1212 Part 2 (brass) or Part 3 (plastic)

BS 1312 Part 3 (steel)

BS 1215

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the insect screen?

To allow ventilation

To prevent debris from entering

To prevent insect access and contamination

To provide structural support

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How much clearance is required above the cistern lid for maintenance?

200 mm

250 mm

300 mm

350 mm

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why should ceiling insulation be removed from beneath the cistern?

To prevent the cistern from freezing

To prevent insect entry

To allow heat from the room below to warm it slightly

To avoid structural damage

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can stagnation in linked cisterns be prevented?

By using a screened vent

By having the inlet in one cistern and the outlet in another

By placing the cisterns side by side

By insulating both cisterns

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?