Nec practice test #2

Nec practice test #2

Professional Development

10 Qs

quiz-placeholder

Similar activities

PJH QLASSIC ASSESSMENT SYSTEM COURSE

PJH QLASSIC ASSESSMENT SYSTEM COURSE

Professional Development

10 Qs

Combustion Mock Quiz

Combustion Mock Quiz

Professional Development

15 Qs

CHAPTER 4: PLUMBING FIXTURES

CHAPTER 4: PLUMBING FIXTURES

Professional Development

10 Qs

Understanding Blueprint Basics

Understanding Blueprint Basics

Professional Development

10 Qs

Conduit

Conduit

Professional Development

10 Qs

Crew Leader Responsibilities and Customer Service

Crew Leader Responsibilities and Customer Service

Professional Development

10 Qs

Shashimi Mas Afis

Shashimi Mas Afis

Professional Development

8 Qs

Heating

Heating

Professional Development

5 Qs

Nec practice test #2

Nec practice test #2

Assessment

Quiz

Construction

Professional Development

Practice Problem

Medium

Created by

andrew h

Used 2+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Each multiwire branch circuit shall be provided with a means that will simultaneously disconnect all the ______ conductors at the point where the branch circuit originates.

circuit

grounded

grounding

ungrounded

2.

MULTIPLE CHOICE QUESTION

5 mins • 2 pts

In other than dwelling locations, GFCI protection is required for all single-phase receptacles rated 150v to ground or less, 50A or less and three-phase receptacles rated 150v to ground or less, 100A or less in unfinished portions or areas of the basement.

True

False

3.

MULTIPLE CHOICE QUESTION

5 mins • 3 pts

In addition to the number of branch circuits required by other parts of 210.11 at least _____ 120v, 20A branch circuit shall be provided to supply the bathroom(s) receptacle outlet(s)

one

two

three

four

4.

MULTIPLE CHOICE QUESTION

5 mins • 4 pts

In a dwelling unit, at least one lighting outlet ____ shall be located at the point of entry to the attic, underfloor space, utility room, or basement where these spaces are used for storage or contain equipment requiring servicing.

that is unswitched

containing or controlled by a switch

that is GFCI protected

that is shielded from damage

5.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

For the purposes of 210.71 , examples of rooms that are not meeting rooms include ______.

auditoriums

schoolrooms

coffee shops

all of these

6.

MULTIPLE CHOICE QUESTION

5 mins • 2 pts

Receptacle outlets in meeting room fixed walls shall be installed in accordance with _____.

210.52(A)(1)

210.52(A) and (A)(2)

210.52(A)(1) through (A)(3)

210.52(A)(1) through (A)(4)

7.

MULTIPLE CHOICE QUESTION

5 mins • 6 pts

When sizing a feeder for the fixed appliance loads in dwelling units, a demand factor of 75 percent of the total nameplate ratings can be applied if there are ______ or more appliances fastened in place on the same feeder.

two

three

four

five

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?