2391 Inspection & Testing Questions

2391 Inspection & Testing Questions

1st Grade

•

40 Qs

quiz-placeholder

Similar activities

Types of Economies & Econ Sectors

Types of Economies & Econ Sectors

9th Grade

•

40 Qs

Developmental Reading

Developmental Reading

7th Grade

•

40 Qs

PENILAIN PRAMUKA AKHIR SEMESTER 1

PENILAIN PRAMUKA AKHIR SEMESTER 1

10th Grade

•

42 Qs

Euroopa päeva viktoriin

Euroopa päeva viktoriin

KG - University

•

35 Qs

IT in BUSINESS: DATA WAREHOUSE

IT in BUSINESS: DATA WAREHOUSE

University

•

37 Qs

SOAL PTS GENAP BAHASA INDONESIA XI TKR/AK 2021

SOAL PTS GENAP BAHASA INDONESIA XI TKR/AK 2021

11th Grade

•

35 Qs

9/8/2020 Academy Day Challenge!

9/8/2020 Academy Day Challenge!

9th - 10th Grade

•

36 Qs

Pemrograman Web dan Perangkat Bergerak Kelas 12 RPL 2

Pemrograman Web dan Perangkat Bergerak Kelas 12 RPL 2

12th Grade

•

35 Qs

2391 Inspection & Testing Questions

2391 Inspection & Testing Questions

Assessment

Quiz

•

Other

•

1st Grade

•

Practice Problem

•

Hard

Created by

Craig Robinson

Used 4+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

OSG gives the maximum stable value of Ze for a TT installation as:

1660 ohms

600 ohms

200 ohms

100 ohms

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which type of earthing system relies on a separately supplied earth, usually the sheathing on the cable?

TT

TN-C-S

IT

TN-S

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following would not be one of the human senses to use during the initial verification of an addition to a lighting circuit:

Sight

Hearing

Taste

Touch

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

On a standard TT installation, the result of the resistance of the earth electrode and the rated RCD residual operating current should not exceed:

25V

50V

110V

400V

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which of the following protection devices is unlikely to be suited for short circuit currents in the region of 6kA:

BS 3036 semi-enclosed fuse

BS 88-3 cartridge fuse

BS 88-2 general purpose fuse

BS EN 60898 circuit breaker

6.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

The term given to the person responsible for an electrical system is the:

Competent person

Electrician

Duty holder

Company manager

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Regional electricity companies quote a maximum likely value of external loop impedance (outside the consumer's installation) for a TN-S system as:

0.35 ohm

0.8 ohm

21 ohm

200 ohm

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?