1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When installing any type of access fitting onto a sealed system the fitting should be __________ before proceeding with recovery.

on the evaporator

removed

on the condenser

leak tested

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To ensure that all CFC, HCFC, or HFC refrigerant has been removed from a frost-free refrigerator, the __________ can be energized to increase the refrigerant's temperature and vaporize any liquid.

condenser fan motor

evaporator fan motor

defrost heater

compressor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Because __________ tend to leak over time, they should not remain on the refrigeration systems after completion of the repair.

A. schrader valves

B. solderless type piercing valves

C. service valves

D. all answers are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An appliance with an operating compressor and completely restricted capillary tube or metering device requires __________.

only one access valve on the low side of the system

only one access valve on the high side of the system

two access valves on the system

two access valves on the high side of the system

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A __________ recovery process for small appliances can capture refrigerant in a non-pressurized container.

passive, self-contained

active, system-dependent

passive, system-dependent

active, self-contained

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the pressure in an appliance is at __________ after installing and opening a piercing access valve, the recovery procedure cannot begin.

0 psig

100 psig

10" Hg.

4" Hg.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When using the __________ recovery process and the compressor does not run, both the high and low side of the system must be accessed for refrigerant recovery.

system-dependent (passive)

system-dependent (active)

self-contained (passive)

self-contained (active)

Access all questions and much more by creating a free account