Professional Electrical Engineering Quiz 4 part 2

Professional Electrical Engineering Quiz 4 part 2

University

48 Qs

quiz-placeholder

Similar activities

Math 8 STAAR Review

Math 8 STAAR Review

KG - University

44 Qs

[Algebra 2] Sem 1 Review

[Algebra 2] Sem 1 Review

9th Grade - University

50 Qs

TIU: NUMERIK (Deret Angka dan Huruf)

TIU: NUMERIK (Deret Angka dan Huruf)

KG - Professional Development

50 Qs

Review for EOC #1  4.18.18

Review for EOC #1 4.18.18

7th Grade - University

50 Qs

Solving One-Step Equations Test

Solving One-Step Equations Test

University

52 Qs

Series Alfanuméricas 13_Universidad_2023

Series Alfanuméricas 13_Universidad_2023

University

50 Qs

RME Pre-board (2021) PEC&TECHNICAL

RME Pre-board (2021) PEC&TECHNICAL

University

48 Qs

NU_CALCULUS II COMPETITION

NU_CALCULUS II COMPETITION

University

50 Qs

Professional Electrical Engineering Quiz 4 part 2

Professional Electrical Engineering Quiz 4 part 2

Assessment

Quiz

Mathematics

University

Easy

Created by

Dem Louise

Used 6+ times

FREE Resource

48 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which is not a characteristic of an ideal transformer?

finite permeability

Infinite permeability

No losses

No leakage flux

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Two capacitors in series are charged across a 24 V source. If C₁ is 12 picofarads, and the voltage across it is 6 V, find C₂.

6 pF

8 pF

2 pF

4 pF

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Two million cubic meters of water is stored in a reservoir feeding a water turbine. If the center of mass of that volume of water is 50 m above the turbine and losses are negligible, how much power in MWHR per second will that volume of water produce? The density of water is 993 kg/m³.

135

253

271

293

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A three-phase, wye connected, 20 MW load of power factor 0.866 lagging is to be supplied by a transmission line at 138 kV. It is desired that the line losses not exceed 5 percent of the load. If the per phase resistance of the line is 0.7 Ω/km, what is the maximum length of the line?

51 km

42 km

63 km

56 km

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Based on the Philippine Distribution Code (PDC), the Distributor may establish penalties for Users whose power factors are less than

90%

85%

80%

75%

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is defined as the total number of sustained Customer power Interruptions within a given period divided by the total number of Customers served within the same period.

System Average Interruption Frequency Index

System Average Interruption Duration Index

Customer Average Interruption Frequency Index

Customer Average Interruption Duration Index

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many 240 V, 20 A branch circuits are required to supply 63,000 VA load?

13

14

15

12