UA Star Review - Quiz 2

UA Star Review - Quiz 2

Vocational training

10 Qs

quiz-placeholder

Similar activities

MTL2 Learner Outcome 3

MTL2 Learner Outcome 3

12th Grade

8 Qs

6072-51 LO1 Identifying Hazards

6072-51 LO1 Identifying Hazards

12th Grade

12 Qs

B4 Quick Squiz Quiz

B4 Quick Squiz Quiz

KG - University

12 Qs

Chapter 7 (1) : Electrical Installation Systems

Chapter 7 (1) : Electrical Installation Systems

University

10 Qs

Water Efficiency and Sustainable Drainage Systems Quiz

Water Efficiency and Sustainable Drainage Systems Quiz

12th Grade

10 Qs

Activity 6 Module 1 Gas Safety Legislation

Activity 6 Module 1 Gas Safety Legislation

KG - University

10 Qs

Low Carbon Steel ppt2 Quiz

Low Carbon Steel ppt2 Quiz

KG - University

15 Qs

UA Star Review - Quiz 2

UA Star Review - Quiz 2

Assessment

Quiz

Construction

Vocational training

Medium

Created by

Brian Downey

Used 54+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Electric alarm devices shall be installed in accordance with what standard?

NFPA-70

NFPA-13

NFPA-72

NFPA-25

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

If water requirements call for more than one fire pump to operate, the pumps shall start ____.

at intervals of 5-10 seconds

within 45 seconds

at the same time

at intervals of 90 seconds

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Electrical systems can be grounded/bonded to underground sprinkler piping _____.

when the AHJ determines that the planned grounding connection is inadequate

if the electrical system(s) do not exceed 240 volts

never

only if underground piping is ductile iron and buried a minimum of 8' below grade.

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Building lightning-protection may be grounded/bonded to underground sprinkler pipe.

True

False

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Mechanical waterflow alarm devices, including but not limited to water-motor gongs, shall be tested ____.

quarterly

monthly

semi-annually

annually

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

During main drain testing, the cause of a reduction of pressure and flow must be identified and corrected, if necessary, when there is a ____ percent reduction in full flow pressure.

3

5

10

20

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

When flexible sprinkler hose is supported in a suspended ceiling, the unsupported length shall not exceed ___.

48"

5'

6'

There is no requirement. Flexible hoses are supported by listed brackets.

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?