Quality Control in Computed Radiography

Authored by Ritika Bera

Science

University

Used 1+ times

Quality Control in Computed Radiography
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which of the following correctly describes the relationship between luminescence and radiation exposure in a CR system?

Luminescence is inversely proportional to radiation exposure

Luminescence has no relationship with radiation exposure

Luminescence is directly proportional to radiation exposure

Luminescence depends solely on the type of laser used

2.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

In the Imaging Plate (IP), what is the approximate thickness range of the phosphor layer that stores the latent image?

5-10 micrometers

100-300 micrometers

500-1000 micrometers

10-20 micrometers

3.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is the primary function of the workstation in the CR Image Display System?

To scan the imaging plate

To provide tools for analyzing, manipulating, and interpreting digital images

To convert digital images into hard copy films

To erase the residual latent image from the imaging plate

4.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which layer in the Imaging Plate construction acts as the backbone and provides mechanical strength?

Reflective Layer

Supportive/Base Layer

Backing Layer

Conductive Layer

5.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is one of the primary reasons for image artifacts caused by static discharge in a CR system?

Improper laser scanning

Absence or malfunction of the conductive layer in the Imaging Plate

Use of low-resolution monitors in the Image Display System

Overheating of the Laser Printer

6.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which of the following layers in the Imaging Plate enhances the efficiency of light collection by reflecting emitted light towards the photodetector?

Protective Layer

Reflective Layer

Conductive Layer

Backing Layer

7.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

The phosphor material commonly used in Computed Radiography imaging plates is:

Calcium Tungstate

Barium Fluorohalide doped with Europium

Selenium Photoconductor

Cesium Iodide with Thallium

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?