Quality Control in Computed Radiography

Quality Control in Computed Radiography

University

12 Qs

quiz-placeholder

Similar activities

Ocean Zones and Lifestyles

Ocean Zones and Lifestyles

8th Grade - University

15 Qs

Nuclear Medicine Intro

Nuclear Medicine Intro

University

12 Qs

Plate Boundaries and Layers of the Earth

Plate Boundaries and Layers of the Earth

6th Grade - University

15 Qs

Earth Layers and Plate Tectonics

Earth Layers and Plate Tectonics

6th Grade - University

15 Qs

Computed Radiography Quiz

Computed Radiography Quiz

University

10 Qs

ROUND 1

ROUND 1

University

10 Qs

Layers of the Earth

Layers of the Earth

6th Grade - University

15 Qs

BOOTCAMP SC.7.E.6.1 EQUIVALENT EXPERIENCE

BOOTCAMP SC.7.E.6.1 EQUIVALENT EXPERIENCE

6th Grade - University

11 Qs

Quality Control in Computed Radiography

Quality Control in Computed Radiography

Assessment

Quiz

Science

University

Easy

Created by

Ritika Bera

Used 1+ times

FREE Resource

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which of the following correctly describes the relationship between luminescence and radiation exposure in a CR system?

Luminescence is inversely proportional to radiation exposure

Luminescence has no relationship with radiation exposure

Luminescence is directly proportional to radiation exposure

Luminescence depends solely on the type of laser used

2.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

In the Imaging Plate (IP), what is the approximate thickness range of the phosphor layer that stores the latent image?

5-10 micrometers

100-300 micrometers

500-1000 micrometers

10-20 micrometers

3.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is the primary function of the workstation in the CR Image Display System?

To scan the imaging plate

To provide tools for analyzing, manipulating, and interpreting digital images

To convert digital images into hard copy films

To erase the residual latent image from the imaging plate

4.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which layer in the Imaging Plate construction acts as the backbone and provides mechanical strength?

Reflective Layer

Supportive/Base Layer

Backing Layer

Conductive Layer

5.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

What is one of the primary reasons for image artifacts caused by static discharge in a CR system?

Improper laser scanning

Absence or malfunction of the conductive layer in the Imaging Plate

Use of low-resolution monitors in the Image Display System

Overheating of the Laser Printer

6.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

Which of the following layers in the Imaging Plate enhances the efficiency of light collection by reflecting emitted light towards the photodetector?

Protective Layer

Reflective Layer

Conductive Layer

Backing Layer

7.

MULTIPLE CHOICE QUESTION

10 sec • 1 pt

The phosphor material commonly used in Computed Radiography imaging plates is:

Calcium Tungstate

Barium Fluorohalide doped with Europium

Selenium Photoconductor

Cesium Iodide with Thallium