Module 26111-17 Exam: Residential Electrical Services

Module 26111-17 Exam: Residential Electrical Services

10th Grade

37 Qs

quiz-placeholder

Similar activities

PPKN FASE E-BAGIAN 3 DAN 4

PPKN FASE E-BAGIAN 3 DAN 4

9th - 12th Grade

35 Qs

GMS summative 3/4

GMS summative 3/4

9th - 12th Grade

34 Qs

Comunicació i xarxes (II)

Comunicació i xarxes (II)

10th Grade

32 Qs

Ch. 11 Consumer Rights Review

Ch. 11 Consumer Rights Review

9th - 12th Grade

40 Qs

Electricity & Electronics - Ch. 5 Circuit Materials Review

Electricity & Electronics - Ch. 5 Circuit Materials Review

10th - 12th Grade

42 Qs

MLA quiz

MLA quiz

6th - 10th Grade

40 Qs

belajar bersama AIR CONDITIONER dan LINEDELIER

belajar bersama AIR CONDITIONER dan LINEDELIER

1st - 10th Grade

38 Qs

Just for Fun

Just for Fun

9th - 12th Grade

40 Qs

Module 26111-17 Exam: Residential Electrical Services

Module 26111-17 Exam: Residential Electrical Services

Assessment

Quiz

Other

10th Grade

Hard

Created by

DIEGO RODRIGUEZ ZAMORANO

FREE Resource

37 questions

Show all answers

1.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

An example of a location in a dwelling where a receptacle must have GFCI protection is a _____.

garage

finished basement

when the receptacle is dedicated to a burglar alarm

crawl space above grade level

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is _____.

Type MC

Type SE

Type AC

Type NM

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A residence with 1,000 square feet of living space has a general lighting load of _____.

1,000VA

2,000VA

3,000VA

4,000VA

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to the NEC®, the small appliance loads in each kitchen area of a dwelling must be served by at least _____.

two 120V, 20A small appliance branch circuits

one 4,050VA small appliance branch circuit

one 1,500VA, 20A small appliance branch circuit

two 240V, 10A small appliance branch circuits

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The NEC® article that provides the rules for demand factors is _____.

NEC Article 110

NEC Article 210

NEC Article 220

NEC Article 230

6.

DROPDOWN QUESTION

30 sec • 1 pt

The NEC® allows the load calculation for the grounded neutral conductor supplying electric ranges and dryers to have a demand factor of (a)   .

50%

70%

85%

100%

7.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Which of the following must never be used as a grounding electrode?

a. a metal underground gas piping system

b. a metal in-ground support structure

c. a ground ring

d. a metal underground water pipe in direct contact with the earth for 10' (3 m)