1.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

A raintight enclosure is constructed or protected so that exposure to a beating rain will not result in the entrance of water under specified test conditions.

True

False

2.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Service-drop conductors shall have

sufficient ampacity to carry the load

adequate mechanical strength

sufficient ampacity to carry the load or adequate mechanical strength

sufficient ampacity to carry the load and adequate mechanical strength

3.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Molded-case circuit breakers are permitted to be reconditioned.

True

False

4.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

An island or peninsular countertop measuring 12 sq ft requires _____ receptacle outlet(s).

1

2

3

4

5.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

In other than dwelling units, GFCI protection shall be provided for all 15A and 20A, 125v, single-phase receptacles installed within ______ ft from the top inside edge of the bowl of a sink.

3

4

5

6

6.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Explanatory material, such as references to other standards, references to related sections of the NEC, or information related to a Code rule, are included in the form of Informational Notes.

True

False

7.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Outside secondary conductors can be of unlimited length without overcurrent protection at the point they receive their supply if the conductors ______.

are protected from physical damage

terminate at a single overcurrent device equal to or less than their ampacity

the overcurrent device is part of the building disconnect

all of these

8.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

The minimum feeder load for show-window lighting is ____ VA per linear foot

180

200

300

400