Auto 2 Finals Quiz 3

Auto 2 Finals Quiz 3

University

20 Qs

quiz-placeholder

Similar activities

QUIZ 2 - CHAPTER  3 & 4

QUIZ 2 - CHAPTER 3 & 4

University

20 Qs

First Hop Redundancy Protocols Quiz chapter 9

First Hop Redundancy Protocols Quiz chapter 9

University

21 Qs

Play with Python Lib

Play with Python Lib

KG - Professional Development

25 Qs

SMJE 2133 Voltage Regulator

SMJE 2133 Voltage Regulator

University

20 Qs

MET quiz

MET quiz

University

15 Qs

Mạng máy tính- Chương 3

Mạng máy tính- Chương 3

University

19 Qs

Power Electronics Activity

Power Electronics Activity

University

17 Qs

Archery Practice

Archery Practice

3rd Grade - Professional Development

20 Qs

Auto 2 Finals Quiz 3

Auto 2 Finals Quiz 3

Assessment

Quiz

Other

University

Medium

Created by

Ralph Cerino

Used 5+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of the Main Switch Board (MSB) Power Management System (PMS) onboard ships?

To manage the engine control room switch boards

To ensure efficient and safe operation of electrical systems

To manage generator operations and electrical load distribution

To monitor crew activities

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is a key feature of redundant power distribution?

Single power source

Automatic Transfer Switches (ATS)

Manual load adjustment

Fixed power pathways

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is load balancing important in power distribution?

To increase fuel consumption

To prevent overload and ensure stability

To reduce the number of generators

To limit power supply to critical systems

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

During a blackout, which systems are prioritized for power restoration?

Entertainment systems

Navigation and safety systems

Crew quarters lighting

Galley equipment

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a component of the main switchboard system?

Automatic Transfer Switches

Stepdown transformer

Governor

Load balancing mechanisms

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What ensures redundancy in power distribution systems?

Single generator operation

Dual power sources and standby generators

Manual power switches

Multiple switchboards

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Load Management & Control Load sharing control systems ensure:

Balanced distribution of load among generators

Only one generator operates at a time

Manual adjustment of generator output

None of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?