ASTM D4530

ASTM D4530

Professional Development

8 Qs

quiz-placeholder

Similar activities

Quiz Pesticide Residue Section

Quiz Pesticide Residue Section

University - Professional Development

10 Qs

Carbon and its Allotropes (Diamond)

Carbon and its Allotropes (Diamond)

8th Grade - Professional Development

12 Qs

Reaction Kinetics

Reaction Kinetics

University - Professional Development

10 Qs

A-B TITRATION AND MOLARITY

A-B TITRATION AND MOLARITY

Professional Development

12 Qs

Molarity Problems

Molarity Problems

10th Grade - Professional Development

10 Qs

Molarity Calculations

Molarity Calculations

10th Grade - Professional Development

10 Qs

PH Calculations Involving Molarity

PH Calculations Involving Molarity

10th Grade - Professional Development

10 Qs

Calculating Moles and Molarity

Calculating Moles and Molarity

10th Grade - Professional Development

10 Qs

ASTM D4530

ASTM D4530

Assessment

Quiz

Chemistry

Professional Development

Hard

Created by

Aplikasi LEMIGAS

FREE Resource

8 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following equations is used to calculate percent residue?

(A-W)W x100

(Ax100)/W

A/Wx100

(A+W)/100 x 0.01

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

For values up to 10% report the value obtained as Micro Method carbon residue, percent to the nearest ____ % (m/m)

0.001

0.01

0.1

1.0

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The thermocouple located in the oven shall be in constant contact with the sample vials during testing

True
False

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The nitrogen purge may be shut off

After the 15 minute hold at 500 oC

After furnace power is shut off

While the oven is cooling

After samples are removed from the oven

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The large 4-dram glass sample vials are for samples:

at risk of component loss due to splattering

suspected to contain ash-forming constituents or non-volatile additives

that require heating

expected to yield residues <0.10% (m/m)

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Samples expected to be below 0.10% weight % (m/m) residue should be distilled to remove ___ % (v/v) of the flask charge

70

80

90

100

7.

MULTIPLE SELECT QUESTION

1 min • 1 pt

Which of the following methods are acceptable to prepare solid materials for transfer. (sellect all that apply)

Dissolving in acetone

Chipping off smaller pieces with a chisel

Freezing with liquid nitrogen and then shattering

Heating

8.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Distillation of a 100 mL sample be discontinued when ___ mL of distillate has been collected​

80

86

88

990