Search Header Logo

Day 2 Net+ Review

Authored by Terry Deckard

Computers

Professional Development

Used 1+ times

Day 2 Net+ Review
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A network technician is troubleshooting a loss of connectivity for several users. After interviewing users, the technician checks the switch logs and performs a physical inspection of the cabling in the server room. According to the CompTIA Network+ troubleshooting methodology, which step is the technician currently performing?

  1. Establishing a plan of action

  1. Identifying the problem

  1. Testing a theory to determine the cause

  1. Verifying full system functionality

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

After implementing a fix for a network outage, what is the NEXT step a technician should take according to the standard troubleshooting methodology?

  1. Document their findings, actions, and outcomes.

  1. Immediately move on to the next trouble ticket.

  1. Verify the solution and confirm full system functionality with the customer.

  1. Establish a new theory of probable cause.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A technician is unable to resolve a complex network problem and suspects it may be related to a faulty hardware component still under warranty. What is the MOST appropriate action for the technician to take next?

Replace the component themselves to save time.

Ignore the warranty and continue troubleshooting.

  1. Escalate the issue to a more senior team member or the vendor.

  1. Advise the customer to accept the problem as a workaround.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A network engineer is choosing a cable for a new building's network infrastructure. The cable will be run through environmental air handling spaces, like drop-down ceilings used for HVAC return air. Which cable type MUST the engineer choose to meet fire safety codes?

  1. Shielded Twisted Pair (STP)

  1. Riser-rated cable

  1. Plenum-rated cable

  1. Coaxial cable

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following Ethernet standards operates at 10 Gbps and is designed to be used with Single-mode Fiber (SMF) over long distances?

  1. 10GBase-T

  1. 10GBase-SR

  1. 10GBase-LR

  1. 40GBase-T

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A technician needs to create a straight-through Ethernet cable to connect a computer to a wall jack. Which wiring standard(s) should be used on both ends of the cable?

T568A on one end and T568B on the other.

  1. T568A on both ends.

  1. Either T568A on both ends or T568B on both ends.

  1. Any combination of standards, as the pins will auto-negotiate.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A network is experiencing a high number of collisions. Which of the following devices, when used to replace an existing hub, would segment the network into separate collision domains and eliminate this problem?

  1. A switch

  1. A repeater

  1. A media converter

  1. An access point

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?