1.

Type of Circuit = Lighting, Wire size = 1 mm2. Number of circuit ?

a)

1

b)

=>2

c)

2

d)

3

2.

Type of Circuit = socket outlets 10 A, Wire size = 2.5 mm2. number of maximum double socket outlets at living and bed rooms per circuit ?

a)

1

b)

10

c)

11

d)

12

3.

Type of Circuit = socket outlets 10 A, Wire size = 2.5 mm2. number of maximum double socket outlets at kitchen per circuit ?

a)

1

b)

2

c)

3

d)

4

4.

Type of Circuit = socket outlets 15 A or 20 A, Wire size = 2.5 mm2. number of circuit ?

a)

1

b)

2

c)

3

d)

4

5.

what should be the cable size for sub-mains to garage or out-building

a)

1 mm2

b)

2.5 mm2

c)

6 mm2

d)

4 mm2

6.

what should be the cable size for mains cable ?

a)

1 mm2

b)

2.5 mm2

c)

6 mm2

d)

16 mm2

7.

What should be rating for main isolator in switchboard ?

a)

100 A

b)

63 A

c)

16 A

d)

6 A

8.

First digit:Protection from the amount of dust that would not interfere with the operation of the equipment.

And

Second digit: Protected against short periods of immersion in water between 15cm and 1m.


What should be the IP rating ?

a)

IP57

b)

IP67

c)

IP66

d)

IP00

9.

First Number: Dust tight

And

Second Number: No special protection


What should be the IP rating ?

a)

IP60

b)

IP67

c)

IP66

d)

IP00

10.

First Number: Dust tight

And

Second Number: Protected against long, durable periods of immersion in water, under pressure


What should be the IP rating ?

a)

IP60

b)

IP67

c)

IP68

d)

IP00

11.

CoC =

a)

Certificate of of Compliance

b)

Coco Cola

c)

Certificate of come-on-time

d)

All of them

12.

Switchboard is allowed to be located:

a)

between 1.2 m and 2 m

b)

Less than 1.2 m

c)

greater than 2 m

d)

none of them

13.

Power socket outlet is allowed to be located:

a)

between 250 mm to 300 mm

b)

between 300 mm to 600 mm

c)

between 600 mm to 900 mm

d)

between 900 mm to 1200 mmm

14.

what is the maximum allowable time for RCD to trip ?

a)

30 ms

b)

300 ms

c)

30 s

d)

300 s

15.

As per figure, what is the maximum allowable imbalance current to trip ?

a)

30 ms

b)

30 mA

c)

300 ms

d)

300 mA

16.

MEN in Electricity ?

a)

Multiple Earthed Neutral System

b)

Plural of Man

c)

Main Earthing

d)

Main Neutral

17.

RCD ?

a)

Red color Device

b)

Residual Current Device

c)

Reverse Compact Disk

d)

None of them

18.

What is the color of Neutral at TPS cable in NZ ?

a)

Blue

b)

Black

c)

White

d)

Brown

19.

CABLE INSULATION TYPES for Main grounding ?

a)

TPS

b)

PVC

c)

Nothing

d)

Do not know

20.
A continuous flow of electricity is called_____________
a)
series
b)
circuit
c)
static
d)
current
21.

How much weight can be carried out by 1 mm2 flex cable ?

a)

5 kg

b)

3 kg

c)

2 kg

d)

1 kg

22.

How much weight can be carried out by .5 mm2 flex cable ?

a)

5 kg

b)

3 kg

c)

2 kg

d)

1 kg

23.

MCB rating for Electric Range(OVEN)

a)

32 A

b)

16 A

c)

6 A

d)

10 A