WorksheetsQC LAB
Total questions: 30
Worksheet time: 15mins
Considered to be the calcium salt choice for intravenous use
silver nitrate
calcium gluconate
sodium chloride
calcium carbonate
Limit tets for chlorides: Precipitate
silver nitrate
barium chloride
silver chloride
barium sulphtae
Limit test for Chlorides: Precipitant
silver nitrate
barium chloride
silver chloride
barium sulfate
Limit test for Sulfates: Precipitant
Barium sulfate
Barium Chloride
Hydrochloric acid
silver nitrate
Method of analysis that deals with the measurement of spectra
Spectrum
Electromagnetic Spectroscopy
Color Spectroscopy
Spectroscopy
Components of Electromagnetic Spectrum: Gamma
<0.1mm
>0.1mm
<0.1nm
1nm
Components of Electromagnetic Spectrum: Visible
380-750mm
380-750nm
<380nm
<380mm
Length of complete wave from the peak of one wave to the peak of the next
wavelength
wave number
frequency
radiowaves
Near IR
3-15um
380-780nm
780-3000um
780-3000nm
Near UV
380-780nm
200-380nm
380-780um
200-380um
The larger the frequency the smaller the wavelength
False
Tralse
True
In order to obtain a fine light spectrum, the atoms must be in gas phase, meaning sample has to be vaporized
UV Spectroscopy
Visible Spectroscopy
Spectroscopy
Infrared Spectroscopy
Most widely used region with molecular vibration typically involved in organic molecules
Near IR
Mid IR
Far IR
Principally concerned with rotational spectral and crystal lattice vibrations
Near IR
Mid IR
Far IR
Identification of molecule as a whole
Near IR
Skeletal Vibration
Characteristics Group Vibration
FTIR
Used for covalently bonded compounds containing different elements
IR
FTIR
AAS
AES
In FTIR, Water is used as a solvent
True
False
Used to examine solid and powder samples
FTIR
IR
DRIFTS
ATR
Used in assay of mettalic elements in blood
Visible Spectroscopy
Infrared Spectroscopy
Flame Spectroscopy
FTIR
Flame Photometry
AES
AAS
Analysis of certain trace elements
AES
AAS
Solid substance are totally converted into liquid form
Complete Disintergration
Complete Dissolution
Disintegration
Dissolution
Maintained temperature of disintegration media
35-39C
37-39C
36-38C
Specs; Plain Coated
1hr
30mins
30seconds
15mins
Specs; Buccal Tablet
2hrs
3hrs
4hrs
1hr
Crushing strenght
Hardness Test
Friability Test
Thickness Test
Disintegration test
Instrument: Air pump
Erweka
Srong Cobb
Stokes Monsanto
Roche Friabilator Condition
104 revolutions 1min
100 revolutions 4mins
4 revolutions 100mins
100 revolutions 5mins
If % loss is less than 1% repeat the test TWICE
True
False
Ability to withstand abrasion in packaging, handling and shipping
Hardness
Hardness Test
Friability
Friability Test
