Gas Core Safety 6035-03 Level 3

Total questions: 28

Worksheet time: 14mins

Name
Class
Date
1.

Which image shows a Natural Draught Flue?

a)
b)
c)
d)
2.

Which image shows a Open Flue?

a)
b)
c)
d)
3.

Which of the following materials will be suitable for a condensing appliance chimney?

a)

Copper

b)

Mild Steel

c)

Stainless Steel

d)

Plastic

4.

When a natural draught room-sealed flue terminal is located below a plastic gutter, a heat shield will be required if the terminal is closer than which of the following measurments?

a)

300 mm

b)

600 mm

c)

1000 mm

d)

1200 mm

5.

Condensation in conventional natural draught open-flue Systems can be reduced by which of the following?

a)

Reduce the length of the flue run internally

b)

Increase the length of the flue run externally

c)

Using a double wall metallic Chimney with an air gap only for the flue length greater than 2 metres

d)

Using insulated double wall metallic chimney

6.

Which is a full-bore valve?

a)
b)
c)
d)
7.

In a litchen with a NG cooker with no openable window to outside the ventilation requirements will be met if?

a)

There is extract ventilation of 10L/s located next to hob

b)

There is extract ventilation of 20L/s located next to hob

c)

There is extract ventilation of 30L/s located next to hob

d)

There is extract ventilation of 40L/s located next to hob

8.

What is standing pressure in a low pressure system?

a)

19 mb

b)

19 to 26 mb

c)

19 to 29 mb

d)

21 mb nominal

9.

What is Working pressure in a low pressure system?

a)

19 mb

b)

10 mb

c)

19 to 29 mb

d)

21 mb nominal

10.

What is shown?

a)

U6

b)

E6

c)

G4

d)

G10

11.

A room-sealed flue is stated to be what Category letter?

a)

A

b)

B

c)

C

d)

D

12.

Volume of 1% CO in Air would cause what affects on the human body?

a)

Slight headache

b)

Severe headache, dizziness and nauusea

c)

Severe symptoms leading to death within 15 minutes

d)

Death within 3 minutes

13.

BS 7967 Part 1:2005 describes what?

a)

Open Flue Boilers

b)

Smoke Alarms

c)

Domestic CO detectors

d)

Maximum temperatures of domestic ovens

14.

A Vertex Flue System takes its air for combustion from?

a)

Outside Air

b)

From within the room

c)

From the loft

d)

Does not require air for the combustion process

15.

Annular space should be the following gap

a)

5 mm

b)

20 mm

c)

25 mm

d)

50 mm

16.

A aerial can affect the performance of a flue?

a)

false

b)

True

17.

The void volume in litres of an unlined brick chimney is a minimum volume of?

a)

12 litres

b)

6 litres

c)

4 litres

d)

2 litres

18.

When installing a flue block system how many starter blocks must there be?

a)

1

b)

2

c)

3

d)

4

19.

Ridge terminals with openings on all sides should be located a minimum of how many mm from each other?

a)

1000 mm

b)

500 mm

c)

300 mm

d)

250 mm

20.

A U-duct system is suitable for use with appliance flue types?

a)

C2 and C4

b)

A

c)

B12

d)

C17

21.

An NG Open Flue must not incorporate a 90 degree bend unless it is a powered flue?

a)

True

b)

False

22.

A closure plate is found?

a)

As part of an open flued boiler

b)

As part of a room-sealed boiler

c)

As part of a Flueless free standing cooker

d)

As part of a radiant convector gas fire

23.

Where would you find a flue spigot?

a)

Gas valve

b)

Radiant convector gas fire

c)

Vertex Flue system

d)

Terminal fixture

24.

Any installation which has previously used a solid fuel appliance must for the first time of being used for a NG appliance be?

a)

Inspected by the consumer of gas

b)

Must have a local authority inspection

c)

Chimney swept and tested

d)

The mouth of the opening must be painted white

25.

What is shown?

a)

Flue Guards

b)

Catchment Space Guards

c)

Gas Fire Guards

d)

Frying Baskets

26.

If you are installing a 24 Kw (Net) Open Flued boiler in a room 4.7 (L) x 3.2 (W) x 2.1 (H) what would be the required ventilation vent size?

a)

120 cm2

b)

100 cm2

c)

85 cm2

d)

No purpose ventilation required

27.

If you are installing a 24 Kw (Net) Room sealed boiler in a room 4.7 (L) x 3.2 (W) x 2.1 (H) what would be the required ventilation vent size?

a)

120 cm2

b)

100 cm2

c)

85 cm2

d)

No purpose ventilation required

28.

Adventious ventilation is equivilant to?

a)

100 cm2

b)

35 cm2

c)

50 cm2

d)

125 cm2