_______eaves over required windows not < _____. minimum over from the side & rear property lines
300 mm
600 mm
1000 mm
750 mm
sum of areas of openings must not exceed _____ % of sum of areas of walls
50
20
40
60
Distance of Exits – w/o sprinkler – ____m from exterior exit door, w/ sprinkler will be ____m
45, 50
30,60
45,60
35,65
Width and Height of doors will be not < _____mm in width, not < ______m in height, opening will be 90 degrees and exit way clear width not < 700mm
900, 2.1
800, 2.0
900, 2.0
800, 2.1
If arcade bldg, no chaflan requited notwithstanding the width of public street, <________m
12
13
14
15
nonstructural facing brick, concrete, tile, metal, etc. attached at the backing or structural components for the purpose of ornamentation.
Brick
Face
Stone
Veneer
spacing of rows of seats from back to back – not < ______mm (standard seating)
840
850
860
870
new construction w/c increases the height or area of an existing bldg./structures.
Addition
Renovation
Revision
Alternation
inner courts shall be connected to a street or yard, or by a passageway – at least how many meters
1.0
1.1
1.2
2
if only 2 exits required, shall be placed distance apart not < ____ of the perimeter area.
1/2
1/3
1/4
1/5
Foundations – not < _______ mm below the grade, may encroach ______mm into public sidewalk areas
600,500
600,400
500,300
600,600
Footings must be at least _______ m below grade along national roads, may project not >______mm beyond Property line.
2.4,400
2.5,300
2.3, 400
2.4, 300
a permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk
Balconies
Awning
Canopies
Pantry
Work done on any damaged/deteriorated portion of bldg.
Alternation
Renovation
Demolition
Repair
Window openings for room must have at least _____% of the floor area with a minimum area of _____ sq.m.
20,1
10,2
10,1
20,2
Window openings for baths and toilets must have at least ____ of the floor area with a minimum area of _____ sq.mm
1/20, 250
1/10, 240
1/20, 240
1/30, 240
WHICH IS NOT INCLUDED IN THE EXCEPTION OF BUILDING PERMIT?
Private
Institutional
Public Building
Home center
WHICH ARE NOT INCLUDED FOR THE REQUIREMENTS FOR BUILDING PERMIT
The use or occupancy of proposed work
A description of work to be covered by the permit
Description ownership of lot -TCT
Tax Documents
WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING
Type II
Type III
Type IV
Type I
WHAT TYPE OF CONSTRUCTION IS FOR WOOD CONSTRUCTION
Type II
Type III
Type IV
Type I
WHAT TYPE OF CONSTRUCTION IS FOR WOOD AND MASONRY CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING
Type I
Type IV
Type II
Type III
WHAT TYPE OF CONSTRUCTION IS FOR STEEL, IRON CONCRETE CONSTRUCTION WITH FIRE RESISTANT MATERIALS 1 HR FIRE RESISTIVE RATING
Type I
Type IV
Type II
Type III
Vertical Clearance of awning (undermost surface of the awning or GL) – not < ______m
3
2.7
2.4
2.8
Ventilation or vent shafts – horizontal cross-sectional area not <_____ sq.m per meter height of shaft
0.15
0.10
0.20
0.12
This is where all on site work done
Office
Plant
Construction
Barraks
The width of a stair way if the occupant load of more than 50 shall not be < ____ m
1.2
1.1
1
1.5
The width of a stair way if the occupant load of less than 50 shall not be < ____ m
0.90
1
0.80
0.70
The slope of an exit passage way will have a maximum slope of
1/8
1/50
1/10
1/15
The slope of an exit courts will have a maximum slope of
1/8
1/10
1/12
1/20
The size of room for kitchen must be at least
1.5x3
1.5x2
2x3
1.5mx 2.1
The size of room for human habitation must be at least an area of _____ sq.m. and ______M minimum distance
6,2
7,3
6,3
7,2
The size of bathrooms or toilets must be at least an area of _____ sq.m. and ______M minimum distance
1.2,1.0
1.5, 0.9
1.2,0.9
1.5,1.0
The RATING IN which a material can withstand fire
Fire Resistive Rating
Fire Respective Rating
Fire Protecting Rating
Fire Rating
the number of exits for Mezzanin with 185 sq.m area or more than 18m in dimension will be exits
1
2
3
4
the number of exits for Above 1st storey with 10 occupant ____ exits
1
2
3
4
The minimum row space with backrest will be
700
750
800
850
The maximum rise and run of the stairs will be
200,200
200,250
200,300
250,250
The headroom clearance for stair will be
2.1 m
2.0 m
2.5 m
3
THE GENERAL PROVISION OF PD 1096 OR THE NATIONAL BUILDING CODE OF THE PHILIPPINES ARE!
Safe Construction
Adequate environmental safeguard
Maintain building safety, sanitary and good working conditions
All of the above
THE ENFORCEMENT OF PD1096 ON THEIR RESPECTIVE JURISDICTION IS THE
Mayor
Architect
Engineer
Building Official
The door that will be required if the exit door shall swing to exit travel in hazardous areas w/ 50 or more occupant load
Swing
Panel
Leaf
None
The distance between 2 landings in stairs will be a maximum of
3.0 m
3.1 m
3.6 m
3.5 m
THE BUILDING PERMIT WILL BE NULL OR VOID IF THE CONSTRUCTION DIDN'T COMMENCE D THE WORK IN A PERIOD OF
6 months
12 months
2 years
3 months
THE BUILDING PERMIT WILL BE NULL OR VOID IF THE CONSTRUCTION HAS BEEN ABANDONED FOR HOW MANY DAYS
30days
60 days
120 days
80 days
Systematic dismantling of a bldg in whole or part.
Dismantle
Demolition
Reinstallation
Alternation
Stair with a straight run, the landing will be a maximum of _______ m vertical distance
1.5
1.2
1.3
1.4
Spacing of rows of seats from back to back : rows of 46 seats or more (continental)
450 mm
500 mm
520 mm
550 mm
Spacing of rows of seats from back to back : rows of 45 seats or less (continental)
450 mm
500 mm
550 mm
520 mm
Spacing of rows of seats from back to back : rows of 35 seats or less (continental)
450 mm
500 mm
520 mm
500 mm
Side aisle width will be a minimum of
1.0m
1.1m
1.2m
1.3m