L3 ventelation,flues,combustion

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.

Working pressure is that pressure measured

at the meter when?

a)

All appliances are turned off

b)

3 cooker burners are lit, or any other appliance full on

c)

The supply is open to atmosphere

d)

all appliances turned full on

2.

When an air vent is installed on the internal wall of a

property the vent must be sited not?

a)

less than 450mm from floor level

b)

more than 450mm from floor level

c)

more than 450mm from ceiling level

d)

less than 450mm from ceiling level

3.

The ventilation requirement for open flued

appliances is dependent upon?

a)

the maximum heat input

b)

the maximum heat output

c)

room dimensions

d)

room dimensions

4.

What action should the gas operative take if an air

vent, of adequate size, but fitted with a fly

screen is encountered?

a)

Install another air vent of the same size with a fly screen

b)

Remove the fly screen

c)

Leave the vent and instruct the user to clean regularly

d)

Disconnect the appliance and label as At Risk

5.

An open flued combination boiler with hot water

input of 36kW (gross) and heating input of 21 kW

(gross) is fitted in a kitchen measuring 2.5m by 2.2m

by I .8m. What is the vent free area required?

a)

59.6 cm2

b)

127.1 cm2

c)

186.6 cm2

6.

A 16kW (Net) input open flued boiler fitted in a kitchen, with an external door and openable window, and having a volume of 11m3 also has a gas cooker installed. What ventilation area is required?

a)

45 cm2

b)

95 cm2

c)

No additional ventilation required

7.

A room sealed boiler with a range rated burner from

16 kW to 21 kW (gross) is fitted in a compartment

and set to I 8.5 kW (gross). What is the required

ventilation direct to outside?

a)

94 cm2 both top and bottom

b)

189 cm2 both top and bottom

c)

83 cm2 both top and bottom

d)

200 cm2 both top and bottom

8.

A room sealed combination boiler with hot water

input of 33kW and heating input of 25kW is fitted in a

kitchen measuring 2.5m by 2.2m by I .8m. What is

the vent free area required?

a)

78 cm2

b)

No vent required

c)

114 cm2

9.

The purpose of the top vent installed within a

compartment is to:

a)

Assist the pull of the flue

b)

Supply air for combustion

c)

Remove warm air for cooling

d)

Reduce the pull of the flue

10.

When installing two or more internal ventilators to

provide air for combustion they must be:

a)

all the same size

b)

50% over sized

c)

25% over sized

d)

white in colour

11.

Where an extract fan is in the same room as an air

brick providing air for combustion:

a)

an additional 50cm2 should be added

b)

the fan must be disconnected

c)

the fan can only blow inwards

d)

an additional 100cm2 should be added

12.

Flue blocks installed after 1986, must have a

minimum internal dimension of?

a)

150mm

b)

100mm

c)

90mm

d)

75mm

13.

The minimum void dimension below an appliance

connection on an unlined brick chimney is?

a)

100 mm – 10 litre

b)

250 mm – 12 litre

c)

75mm – 2 litre

d)

80mm – 8 litre

14.

When shielding plastic gutter from a flue terminal the

minimum air gap between the shield and the gutter

should be?

a)

25mm

b)

15m

c)

1mm

d)

5mm

15.

A flue serving a gas fire , on an external wall should

be lined when it is above?

a)

9 metres high

b)

10 metres high

c)

12.5 meres high

d)

15 metres high

16.

An open flued fire with an Oxygen Depletion Sensing

Device is permitted in a Bedroom if?

a)

it is above 14 kW input

b)

it is below 14 kW input

c)

it is below 7 kW input

d)

its input is irrelevant

17.

A precast flue block installation dating from the

1970’s would be expected to have a cross

sectional area of?

a)

12000 mm2

b)

16000 mm2

c)

13000 mm2

18.

The Gas Safety (Installation and Use) Regulations

apply to touring caravans ONLY when

hired out in the course of a business?

a)

True

b)

False

19.

Non-metallic gas pipe can only be used to convey

gas if it is?

a)

black in colour

b)

yellow in colour

c)

a pipe connected to a readily movable flueless appliance or a sleeved pipe entering a building

d)

a pipe connected to a readily movable appliance

20.

Any newly installed gas appliance which CAN

NOT be used safely?

a)

must be labeled, “Do Not Use”

b)

can be left connected to the supply

c)

cannot be left connected to the gas supply

d)

is safe to be left connected providing the user is told of the situation

21.

A tenant agreeing to have safety work done

DISCHARGES the landlord from their obligations

under The Gas Safety (Installation and

Use) Regulations for landlord safety checks?

a)

True

b)

False

22.

Where the responsible person refuses to allow an

unsafe appliance to be disconnected, the

installer shall?

a)

turn off appliance and inform TRANSCO

b)

inform Gas Safe Register

c)

do nothing to the appliance

d)

turn off appliance and write to the responsible person

23.

A gas fire and back boiler of inputs 7kW and 16kW

respectively fitted in 1999, in a bed sitting

room. What are the ventilation requirements?

a)

72 cm2

b)

103.5 cm2

c)

80 cm2

d)

Installation not allowed

24.

To convert Btu’s to kW you?

a)

multiply by 3412

b)

divide by 3412

c)

multiply by 1040

d)

divide by 1040

25.

To change the Gross input of an appliance to Net

you?

a)

÷ by 1.11

b)

x by 1.11

c)

÷ by 1.1

d)

÷ by 1.1