When the Wait (W), Alarm or Sample (S) indicators start to flicker side to side on a GID-3 unit, it indicates:
The detector‘s IMS is not functioning
There is a deficiency in the power source
There is unknown vapor detected
The detector had been contaminated
Where should the GID-3 be placed during initial confirmation of CA release?
Staging Point
Between Hot zone and Warm zone boundary
Between Cold zone and Warm zone boundary
Forward Triage Area
The picture below displays an uncut Draeger tube being inserted into the Accuro Gas Detector Hand pump. What type of the hand pump test is being conducted?
Leak test
Positive pressure test
Suction test
Pump test
When the “Chirper Mode” of the Ultra Radiac is activated, which of the following actions can a responder perform?
Estimate the distance and pinpoint the location of the alpha and beta radiation source
Pinpoint the location of the gamma radiation source
Identify the radiation source
Show the dose rate readings of alpha particles
What is the default mode of the FH 40
Counter Mode
Rate meter
Total Dose
Dosage
FH40 alarm will be triggered at which of the following rate (cps)?
50cps
1000cps
100cps
10cps
What is the purpose of the GID-3?
To detect anthrax during an indoor release
To detect nerve, blister, blood & choking agents in the environment
To detect radiological agents during an outdoor release
All of the above
When the “ loudspeaker” is turned on for an Intensimeter unit, the X50 DE will sound with a warning signal if the dose rate exceeds:
1µSv/ Hr
25µSv/ Hr
100µSv/ Hr
250 µSv / Hr
The diagram below, shown on an AP4C detector, indicates :
Overpassing of Unknown Chemicals
Presence of Hydrocarbons
Absence of S4PE
Absence of the sampling nozzle
Which of the following indicates blood or choking detection in Low reading?
What does it means when the following symbol appears of Saphydose.
Battery level is low
Evacuation is required as the Saphydose measure 5 mSv/h
Maintenance is required by vendor
Beta radiation is detected
What is the proper set up procedure of the Intensimeter?
Switch on the X 50 DE; attach to the Telescope Probe; remove rubber cap; ready for use.
Switch on the X 50 DE; attach to the Telescope Probe; wait for self-test; X 50 DE automatically enters into dose rate measurement mode; ready for use.
Attach the X 50 DE to the Telescope Probe; switch on the X 50 DE; wait for self-test; X 50 DE automatically enters into dose rate measurement mode; ready for use.
Attach the X 50 DE to the Telescope Probe; switch on the X 50 DE; wait for self-test; press Toggle Button until dose rate measurement mode; ready for use.
What is the correct way to read the concentration level of a chemical on the Short Colour Metric Draeger tube?
The concentration level of the chemical detected is read off at the level of the tube after the colour change.
The concentration level of the chemical detected is read off at the level of the tube where there is no further colour change.
The concentration level of the chemical detected is read off at the level of the tube before the colour change.
The concentration level of the chemical detected is read off at the level of the tube at the start of the colour change.
Which of the following statements regarding the Intensimeter are true?
i) Press the Switch-over button to switch between Dose and Dose Rate measurement modes.
ii) Press and hold the Search button to use the un-averaged analogue reading to search for the directions of unknown radiation sources.
iii) Fully extend the Telescope Probe to maximise distance from the radiation sources.
iv) The function of the Telescope Probe is interrupted when the Switch-over button is pressed.
i, iii and iv
i & ii
ii, iii & iv
All of the above.
What are the types of Radiation that the Ultra Radiac can detect?
Gamma
Alpha
Beta
All of the above
When the external probe is attached to the FH40 basic Unit , which of the following particles it can detect?
Alpha & Gamma
Alpha & Beta
Alpha, Beta & Gamma
Alpha, Beta ,Gamma & Neutrons
What could possibly cause the following indicator to appear on the Ultra Radiac display screen?
The Geiger Muller tube has failed and needs repair
High dose rate of 100mSv/hr has occurred and the area is “ HOT Zone”
Dose rate of 5Sv/hr has occurred and immediate evacuation is required
The ULTRA RADIAC self-start up initialization test has failed. The unit needs to be sent back for servicing
When taking background measurement at the Decon Point, what is the minimum distance the monitor of the FH40 should be away from any contaminated object or person?
50cm
100cm
150cm
200cm
When the external probe is attached to the FH40 basic unit, which of the following particles can it detect?
Alpha & Gamma
Alpha & Beta
Alpha, Beta & Gamma
Alpha, Beta, Gamma & Neutrons
What does the FH40 detect without attaching to an external probe?
Dirty bomb with possible alpha contaminants
Radiation incidents with no beta and only alpha contaminants
Radiation incidents with beta and gamma contaminants
Dirty bomb with only gamma contaminants
What is the default mode of the FH40?
Counter mode
Rate meter
Total dose
Dosage
Which of the following gas is the G999 calibrated against for flammability limits?
Propane
Butane
Ethane
Hexane
Which of the following sensors on the G999 can detect and measure chlorine gas?
Infra Red
Thermal Conductivity
Electrochemical
Catalytic Combustion
Which of the following situations will not trigger the alarm of G999?
Exceeding detection range of the EC sensor
Pump fault test fails
Detection of gas below IDLH levels
Detection of gasses below TWA levels
Which of the following 2 gases are present in all configuration of the G999?
CH4 and H2S
CH4 and O2
CH4 and NH3
O2 and NH3
What does the LCD 3.3 detect?
Liquid chemical warfare agents and solid state toxic industrial chemicals
Airborne chemical warfare agents and vapors of toxic industrial chemicals
Radioactive particulates and solid state toxic industrial chemicals
Airborne chemical warfare agents and solid state biological agents
What are the detection modes for the LCD 3.3?
TIC mode, Radiation mode and CWA mode
Identification mode, CWA mode and Standard mode
Standard mode, Survey mode and CWA mode
TIC mode, CWA mode and Survey mode
When responding to an unknown CA release, what mode should the LCD 3.3 be on?
Standard
CWA
Survey
Which of the following detectors uses a hydrogen stocker?
LCD3.3
AP4C
GID3
FH40
In the CWA mode, the LCD3.3 samples the environment once every (a) seconds.