10.11.2020_EC8073_ME_MODEL EXAM-2_PART-B

Total questions: 15

Worksheet time: 15mins

Name
Class
Date
1.
1.A Cardiologist examines a patient and suspects Ventricular Tachycardia abnormality, to diagnose and confirm the same which among the following has to be observed in the patient's ECG? (CO1) (B4).
a)
Improper beat rate in ECG
b)
Overshoots in ECG
c)
Prolongation of QRS Complex
d)
Ripples after T-wave and next P-wave
2.
2.Which among the following types of perception of the heart can be viewed through the 6 Unipolar chest leads? (CO1) (B3).
a)
Primary Plane
b)
Frontal Plane
c)
Horizontal Plane
d)
Virtual Plane
3.
3. Which among the following techniques is connected with the recording of the auscultations through the pumping action of heart ? (CO1) (B4)
a)
EEG
b)
EKG
c)
Echocardiogram
d)
Phonocardiogram
4.
4. For a patient under going a pH test, if the pH value of a body fluid exceeds 7.45, then the body can be diagnosed to be in a state of Alkalosis.<br /> TRUE or FALSE? (CO2) (B4)
a)
true
b)
false
5.
5.Apnoea monitors can be particularly useful to monitor, which among the following activities of premature infant patients? (CO2) (B4).
a)
respiratory activity
b)
circulatory activity
c)
sensing activity in nerves
d)
Digestive system activity
6.
6.While taking BP measurement throurh a sphygmomanometer,The pressure reading in the mercury column at which korotkoff sound is disappeared is noted as diastolic pressure. Validate. (CO2) (B4).
a)
true
b)
false
7.
7. If the pacemaker pulse is found to be too long, in such situation,which among the following circuitry can be used to provide the control?. (CO3) (B4).
a)
Refractory control
b)
Amplitude control
c)
Gain Control
d)
Damping control
8.
8.A patient is suspected with a blood clot in his legs. The physician suspects there may be thickening of blood. He attempts to diagnose whether there is a decreased blood circulation in the patient's leg veins. Which Ultrasound method he should prefer? (CO3) (B4).
a)
A-Mode US Scan
b)
B-Mode US Scan
c)
M-mode US Scan
d)
Doppler Mode US Scan
9.
9.Echoes from moving scatterers (RBCs, Blood clots, Tumors) exhibit slight differences in the time for the signal to be returned to the receiver.These time differences are converted into the shift in frequency of the transmitted signal which is known as _____________________________. (CO3) (B4).<br />
a)
Doppler Frequency
b)
Delta Frequency
c)
Differential Frequency
d)
Daimler Frequency
10.
10.A physician diagrnoses that a patient has a tissue tear (ligament tear) very deep inside the claf muscles in the right leg.Which diathermy he should prescribe the medical attendant for this patient_____________________________________ (CO4) (B4).
a)
Shortwave diathermy
b)
Microwave diathermy
c)
Ultrasonic Diathermy
d)
SW inductothermy
11.
11.In which ofthe following process the body fluids are coagulated with a relatively larger span by spraying the HF wave forms using Electrosurgical diathermy unit? (CO4) (B4).
a)
Cutting
b)
Fulguration
c)
Dessication
d)
Stitching
12.
12. Which block of the telemetry transmitter is responsible for signal amplification,shaping and noise filtering? (CO4) (B4).
a)
Signal Acquisition
b)
Signal Conditioning
c)
Signal Transmission line
d)
Power Amplifier
13.
13.Which medical device is used for the administration of insulin in the treatment of diabetes mellitus?The process of using this device is also known as continuous subcutaneous insulin therapy. (CO5) (B4).<br />
a)
An insulin pump
b)
An insulin injection
c)
An insulin ring
d)
An insulin band
14.
14.______________is the minimal dose of insulin needed to keep blood glucose levels under control, and to allow the cells to take in glucose for energy. (CO5) (B4).<br />
a)
Basal dose
b)
Bolus dose
c)
Blended dose
d)
Benign dose
15.
15.Incorporating __________________________ facility will allow the BMI to transmit only the action potential waveforms and their respective arrival times instead of the sparse, raw signal in its entirety. (CO5) (B4).<br />
a)
Surge measurement
b)
Spike detection
c)
Similiarity detection
d)
Shape detection